background image

40  –  Part 5: Specifications

Part 5: Specifications  –  41

VELUX glass lined solar storage tank (with atmospheric gas backup)

• 

Glass Lined Steel Tank 

 Two Protective Aluminum Anode Rods

• 

R-value of R-17

• 

Internal double wall glass coated steel solar heat exchanger

 Honeywell Self Diagnostic Gas Control 

 Flammable Vapor Ignition Resistant technology (FVIR) 

(TFF 060 2205 and TFF 060 3205) 

 Backup Low NOx Burner (Ultra Low NOx Burner with  

TFF 060 2205) – Comply with SCAQMD Rule 1121. 

• 

T&P Relief Valve – Included 

• 

Brass Drain Valve – Tamper proof 

VELUX solar storage tank dimensions

MODEL #

GAL

Dimensions

A

B

C

D

E

F

G

TFF 060 2205US

60

24”

63”

59

1

2

11

5

8

10

1/

8

32

1

4

53

1

2

TFF 080 2205US

70

26”

62

3

8

59”

14

3

8

12

1

2

34

5

8

52”

TFF 060 3205US

60

24”

63”

59

1

2

11

5

8

10

1/

8

32

1

4

53

1

2

TFF 080 3205US

70

26”

62

3

8

59”

14

3

8

12

1

2

34

5

8

52”

VELUX solar storage tank connections and weight

MODEL #

Solar heat exchanger  

inlet/outlet connections

Hot/cold potable water 

connections

Vent connection

Shipping weight (lbs)

TFF 060 2205US

3/4” NPT

3/4” NPT

4”

272

TFF 080 2205US

3/4” NPT

3/4” NPT

4”

306

TFF 060 3205US

3/4” NPT

3/4” NPT

4”

264

TFF 080 3205US

3/4” NPT

3/4” NPT

4”

306

VELUX solar storage tank specs

MODEL #

Backup 

fuel

Backup 

input rate 

(btu/h)

Solar HX 

volume (gal)

Heated water 

volume of  

back up

Recovery (gph)

First hour supply (gal)

77

º

 rise

90

º

 rise

77

º

 rise

90

º

 rise

TFF 060 2205US

Natural gas

55,000

2.5 gal

60 gal

67

57

109

99

TFF 080 2205US

Natural gas

76,000

2.5 gal

70 gal

92

79

141

128

TFF 060 3205US

LP

63,000

2.5 gal

60 gal

77

66

119

108

TFF 080 3205US

LP

76,000

2.5 gal

70 gal

92

79

141

128

Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into the potable side of this system.  The potable side may NEVER be 

connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.

C

G

F

D

A

Cold water inlet

Temperature and  
pressure relief valve

Aluminum jacket

Drain valve

Hot water 

outlet

Back-Up

burner

Solar heat exchanger

Surface mounted 
solar sensor

Gas control

sensor

E

B

Gas control valve

Solar water heating

Содержание CLI U12 SD0F1110 NG B/U

Страница 1: ...I U12 SK0 W L F P 319 HX B U Solar with heat exchanger back up CLI U12 SD0 W L F P 118 AUX EL CLI U12 SK0 W L F P 218 AUX EL CLI U12 SK0 W L F P 318 AUX EL Solar pre heat to electric tank water heater...

Страница 2: ...sor connection to pump station controller Page 28 Solar loop and potable water piping insulation and support Page 28 Electrical connection electric backup systems only Page 29 Gas connection gas backu...

Страница 3: ...protect against injury you must install the supplied ASSE approved mixing valve in the water system Refer to the instructions supplied with the mixing valve for installation procedures and specificat...

Страница 4: ...uid The solar collector is the engine of the VELUX solar water heating system When the sun is shining the heat energy is absorbed by the solar collector and transferred to the heat transfer fluid circ...

Страница 5: ...lated with the high quality flexible closed cell insulation provided to minimize heat loss There shall be no exposed piping or fittings The wall thickness of the pipe insulation should not be less tha...

Страница 6: ...f air Anti scald mixing valve set to 120 F Systems with electric back up solar tank Power supply voltage agrees with the water heater rating plate Branch circuit wiring and circuit breaker properly si...

Страница 7: ...e used for the solar storage tank heat exchanger circuit only Never introduce Anti freeze solution to any other solar storage tank connection other than the solar heat exchanger 3 If there is a check...

Страница 8: ...n tank suitable for potable water must be sized and installed within this piping system between the check valve and the cold water inlet of the solar water heater 4 The anti scald mixing valve provide...

Страница 9: ...lve on the cold water feed line a thermal expansion tank suitable for potable water must be sized and installed within this piping system between the check valve and the cold water inlet of the solar...

Страница 10: ...ther than the solar heat exchanger 3 If there is a check valve on the cold water feed line a thermal expansion tank suitable for potable water must be sized and installed within this piping system bet...

Страница 11: ...valve discharge line must be no smaller than the outlet of the valve and must be pitched downward from the valve to allow complete drainage of the relief valve and discharge line The end of the discha...

Страница 12: ...ck valves are not installed most of the heated energy stored during the day would be transferred back up into the collectors and lost d Collector array isolation valves Valves located in the hot and c...

Страница 13: ...ontroller to measure the temperature on the bottom of the solar storage tank e VELUX flexible piping Pre insulated corrugated stainless steel flexible piping designed specifically for VELUX solar loop...

Страница 14: ...uildings and trees should be checked for possible winter shading Collector installation The most important structural consideration is to securely anchor the solar collector to the structural members...

Страница 15: ...Part 3 Solar water heater system installation 15 CLI U12 4000 2 Collector layout 16 o c rafters CLI U12 4000 3 Collector layout 16 o c rafters Collector location on 16 o c rafters...

Страница 16: ...16 Part 3 Solar water heater system installation CLI U12 4000 2 Collector layout 24 o c rafters CLI U12 4000 3 Collector layout 24 o c rafters Collector location on 24 o c rafters...

Страница 17: ...collectors measured to the vertical wall casing Secure collector top support flange to roof deck using three self tapping stainless steel mounting screws provided When possible screws shall be located...

Страница 18: ...ided 7 Locate the end of the flexible pipe connected to the bottom left corner of the collector bank this is the heat transfer fluid cold pipe Locate the indicator tab near the end connection Tear off...

Страница 19: ...ure sensor Drill a 1 hole alongside the collector flange near the temperature sensor well Route the cable from the cable wall down through the 1 hole 11 Secure the side flanges of the collectors to th...

Страница 20: ...ing Contractors Association NRCA or other qualified body 1 Install the bottom pan flashings and gutters and secure in place using metal tabs as referenced in the VELUX flashing instructions Do not dri...

Страница 21: ...controller expansion tank mixing valve and other key components The components on the potable side of the system may require future service or maintenance so it is recommended that the connections be...

Страница 22: ...idelines for your VELUX solar water heating system could cause component failure and possible safety issues It is mandatory that all plumbing be done in accordance with all local and state codes or wa...

Страница 23: ...pansion tank flex connector securely to pump station using pipe tape and the gasket provided Tighten the flexible pipe nut securely 3 Adjust flex connector as needed and attach the other end of expans...

Страница 24: ...or hot supply flexible pipe with red tab extend the hot supply past the hot water connection on the pump station remove any excess pipe and prepare the end of the flextube as needed Repeat these steps...

Страница 25: ...and the gasket provided 2 Route the flextubes such that the flextube connected to the air separator is connected to the pump station bottom left connection and the flextube connected to the heat exch...

Страница 26: ...llation guidelines for your VELUX solar water heating system could cause component failure and possible safety issues It is mandatory that all plumbing be done in accordance with all local and state c...

Страница 27: ...onnect 3 4 brass nipples to the mixing valve cold water port C and to the brass tee using pipe tape as shown Tighten both fitting securely 4 Connect the 3 4 copper flexible connector between the mixin...

Страница 28: ...bottom sensor brown wire to the terminals marked T2 and connect the tank top sensor gray to the terminals marked T3 polarity does not matter on these connections Replace the system control front cove...

Страница 29: ...n attachment or use of any type of unapproved devices into onto or in conjunction with this water heater The use of unauthorized energy saving devices may shorten the life of the water heater and may...

Страница 30: ...use of unauthorized energy saving devices may shorten the life of the water heater and may endanger life and property The manufacturer disclaims any responsibility for such loss or injury resulting f...

Страница 31: ...ydamage personal injury or death Provide adequate air for combustion and ventilation An insufficient supply of air will cause recirculation of combustion products resulting in air contamination that m...

Страница 32: ...ater Do this by opening the cold water isolation ball valve to the solar tank Inspect all fittings for leaks Purge all air from the potable water system by turning on several hot and cold faucets and...

Страница 33: ...the fill pump return hose to the pump station drain valve connector 2 Prime the end suction pump 2 Open the fill valve 1 and drain valve 2 Open the hot 3 isolation valve turning it fully counterclock...

Страница 34: ...l indicate the tank bottom temperature P1 will indicate pump speed 0 Off 100 On 2 When temperature T1 is 12 F hotter than T2 the system will begin transfering heat to the solar tank Pump symbol will r...

Страница 35: ...cleaning A hissing sound while operating will happen when the element starts to build up deposits that will require cleaning This should be done only by a qualified individual or licensed plumber Ano...

Страница 36: ...SONAL INJURY FROM CONTACT WITH HOT WATER AND TO AVOID PROPERTY DAMAGE BEFORE operating lever check to see that a discharge line is connected to the valve directing the flow of hot water from the valve...

Страница 37: ...4 F 67 4 42 9 51 6 Absorber K 49 8 41 9 27 8 L 67 7 43 2 51 9 Technical specifications CLR U12 4000 CLI U12 4000 CLI S06 4000 CLI M08 4000 Weight lbs Collector weight 130 130 73 57 Weight w fluid 141...

Страница 38: ...mK R Value R 4 VELUX flextubes feature Flexible corrugated stainless steel tubing Pre installed Armaflex HT insulation with UV inhibitors Brass connection fittings Gasket free conical connections ens...

Страница 39: ...TFF 080 0205US 4 500 240V 1 2 5 gal 75 gal 24 20 77 gal 73 gal TFF 120 0205US 4 500 240V 1 2 5 gal 115 gal 24 20 105 gal 101 gal Two 4 500 watt elements non simultaneous operation Toxic chemicals such...

Страница 40: ...rst hour supply gal 77 rise 90 rise 77 rise 90 rise TFF 060 1205US 2 5 gal 27 gal 13 min 15 min 80 000 BTU HR 144 gal 126 TFF 080 1205US 2 5 gal 37 gal 16 min 18 min 90 000 BTU HR 166 gal 146 TFF 120...

Страница 41: ...Vent connection Shipping weight lbs TFF 060 2205US 3 4 NPT 3 4 NPT 4 272 TFF 080 2205US 3 4 NPT 3 4 NPT 4 306 TFF 060 3205US 3 4 NPT 3 4 NPT 4 264 TFF 080 3205US 3 4 NPT 3 4 NPT 4 306 VELUX solar stor...

Страница 42: ...ections Vent connection Shipping weight lbs TFF 060 4205US 3 4 NPT 3 4 NPT 3 or 4 281 TFF 080 4205US 3 4 NPT 3 4 NPT 4 336 TFF 060 5205US 3 4 NPT 3 4 NPT 3 or 4 281 TFF 080 5205US 3 4 NPT 3 4 NPT 4 33...

Страница 43: ...ximum design pressure 145 psi Maximum temperature sustained 250 F Maximum temperature short term 320 F VELUX solar pump station component technical data Pressure relief valve 87 psi Pressure gauge 0 8...

Страница 44: ...elow 73 C 100 F Recommended use temperature range 45 C 50 F to 150 C 325 F Suitable applications single fluid process heating and cooling closed loop water based HVAC applications where propylene glyc...

Страница 45: ...physical properties Mists may cause irritation of upper respiratory tract nose and throat Remove to fresh air if effects occur consult a physician Note to physician No specific antidote Supportive car...

Страница 46: ...US 1 Pump station controller kit 307354 1 CLI U12 SK0L 219 HX B U Collector CLI U12 4000 2 Flashing system EKL U12 0021E 1 Storage tank TFF 080 1205US 1 Pump station controller kit 307355 1 CLI U12 SK...

Страница 47: ...1 Storage tank TFF 060 1205US 1 Pump station controller kit 307354 1 CLI U12 SK0W 219 HX B U Collector CLI U12 4000 2 Flashing system EKL U12 0021E 1 Storage tank TFF 080 1205US 1 Pump station contro...

Страница 48: ...em ZFT 101 1 Storage tank TFF 060 1205US 1 Pump station controller kit 307354 1 CLI U12 SK0F 219 HX B U Collector CLI U12 4000 2 Rack system ZFT 101 2 Storage tank TFF 080 1205US 1 Pump station contro...

Страница 49: ...U Collector CLI U12 4000 1 Rack system ZFT 100 1 Storage tank TFF 060 1205US 1 Pump station controller kit 307354 1 CLI U12 SK0P 219 HX B U Collector CLI U12 4000 2 Rack system ZFT 100 2 Storage tank...

Страница 50: ...gh hot water System undersized Reduce rate of hot water use Defective element Check amperage replace element Defective thermostat or wired incorrectly Check wiring or replace Solar system controller i...

Страница 51: ...bar Expansion tank too small Properly size and replace expansion tank System pressure too low Propylene glycol leak in system Check system for leaks and repair Expansion tank too small release of pro...

Страница 52: ...r level of freeze protection Valve 1 collector array fill drain valve Warning hot Valve 1 is normally closed When open it is used to charge and drain the solar collector loop piping The heat transfer...

Страница 53: ...Maintenance notes 53 Notes Maintenance notes...

Страница 54: ...mation Installers name Company Address 1 Address 2 City State Zip Phone number Fax number E mail Installation information Collectors Model number Serial number 1 2 3 4 Tank Gallons Aux Orientation Pit...

Страница 55: ...18 AUX EL 2009155B o CLI U12 SK0 W L F P 318 AUX EL 2009155C o CLI U12 SD0 W L F P 118 AUX GAS 2009156A o CLI U12 SK0 W L F P 218 AUX GAS 2009156B o CLI U12 SK0 W L F P 318 AUX GAS 2009156C o CLI U12...

Страница 56: ...142 0311 2011 VELUX Group VELUX VELUX logo are registered trademarks VELUX America Inc 450 Old Brickyard Road PO Box 5001 Greenwood SC 29648 5001 Tel 1 866 99 VELUX Fax 1 864 943 2631 www veluxusa com...

Отзывы: