Veltron DHOE-90 Скачать руководство пользователя страница 8

- 8 -

www.veltron-heaters.com

HOW TO USE

OPERATION & STOP

1. CONNECT POWER PLUG 

(You can see current temperature) 

THEN, PRESS ON/OFF BUTTON

(You can check “set tem/time“-the number of right side)

But, if this heater operate in cas

e fi

 rst use from purchase, turn Air 

Screw left around three times and then start with pressing “ON/

OFF“ switch. Heater will be turned ON with “beep“ sound, and 

automatically operated. Fasten the air screw after 4 seconds. 

If “E1“ error is displayed, press “ON/OFF“ switch one more time.

2. SELECT THE DESIRED OPERATION TYPE USING “TEMP or
TIME“ BUTTON.

3. Set the time or temperature by pressing “Temp select button“ or “Time select button“.

- “Temperature“: You can set the desired temperature between “0~40°C“

- “Time“: Set the desired time limit between “10~25min“ (5min per a press)

  

Tip

• In order to be operated, the setting temperature should be higher than current temperature.

• After power On, the default mode is temperature control mode.

• During the operation if you push On/O

ff

  button, the heater is stop and the o

ff

  timer function is cancelled.

Circulation Fan operate in a minute after turning on heater and stop in two minutes after turning o

ff

  heater.

(This fan is for circulating heat and for cooling heater)

The model equipped “solenoid valve (by-pass device) makes the remaining oil returned to the oil tank. For 10sec. from the time of 

burner 

off

 , the solenoid valve is operation, which makes remaining oil returned to the oil tank, and by this device, the smell caused 

by unburned gas are remarkably shrunk.

Cur Temp

Cur Temp

Set Temp/Time

Set Temp/Time

Содержание DHOE-90

Страница 1: ...on where the user can find easily It is obligatory that the user read Notice for Safety carefully before using and should be aware of this notice whenever using this heater This heater is designed for...

Страница 2: ...RE DESCRIPTION FOR MODEL 6 CONTROLLER 6 REMOTE CONTROLLER 7 HOW TO USE 8 10 OPERATION STOP 8 TEMPERATURE CONTROL 9 SELF DIAGNOSIS FOR THE SAFETY DEVICE 10 CLEANING MAINTENANCE 11 DAILY CHECK POINTS AD...

Страница 3: ...to turn OFF this heater by taking out the power plug It may cause a malfunction or electrical shock Please turn OFF using RUN STOP button Put a plug into the outlet tightly with Earth only It may cau...

Страница 4: ...just after extinguish ing the grill and furnace are hot so do not touch any of those parts Especially pay attention more to keep children away from the hot materials It may cause a burn Do not move or...

Страница 5: ...all spaces It is recommended but not required Take a look at the drawing Recommended Duct specification 75mm Diameter x 5meter long aluminum duct Be sure there must not be rain drops into the exhaust...

Страница 6: ...sensor Fuse Burner department Circulation Fan Conduction Sensor Fuel Guage Fuel inlet Temperature Sensor Fuel Filter 1 LED DISPLAY It displays the status of temperature time operation and error etc 2...

Страница 7: ...OL 1 ON OFF When heater tums ON or OFF you can this button 2 OFF TIMER Every time you press this button heater repeat set up and cancel 3 TIME SELECT BUTTON To select time control mode 4 TEMP SELECT B...

Страница 8: ...sired temperature between 0 40 C Time Set the desired time limit between 10 25min 5min per a press Tip In order to be operated the setting temperature should be higher than current temperature After p...

Страница 9: ...is less than 1 C than current temp the operation is stop Current temp Setting temp Opeartion 2 C Current temp Setting temp Opearation stop 1 C Tip The current temp is less than 9 C 16 F the dispaly of...

Страница 10: ...onnectong the wire E6 Lack of fuel Lack of fuel Refuel Re operation Hi Temperature is above 50 C Check if the tempatature sensor is installed inside Install the sensor outside If the troubles E1 E6 oc...

Страница 11: ...the heater for a long time and you want to maintain it in clean status please power off and cool down the heater and pull out the plug as the above picture and clean according to the following instruc...

Страница 12: ...e sure CdS is fixed correctly Mark A should be inserted fully CLEAN OF COMPONENTS In case you need to change components please contact us In case repair or exchange of components please contact the se...

Страница 13: ...oil If oil is all consumed without remaining in the tank air can be flow into inside electric pump The method to flow out air Operate the heater When the electric pump operated turn on the air outflo...

Страница 14: ...erheating prevention Ventilate with fresh air in the room and turn OFF the heater for a while Refer to page 16 Inclination display lamp ON Ground surface is in clined or not plain Replace the heater i...

Страница 15: ...se in fuel pump Excessive air in the pump and nozzle Remove the air in the electric pump EXCESSIVE SOOT IS GENERATED Check if the fuel is Diesel or kerosene It may cause less per formance trouble Drai...

Страница 16: ...x 800 940 x 320 x 1020 1290 x 320 x 1020 1290 x 320 x 1190 1290 x 320 x 1190 1340 x 350 x 1510 1370 x 400 x 1800 Weight 42 kg 45 kg 60 kg 63 kg 63 kg 90 kg 116 kg Used Heating Heating Heating Heating...

Страница 17: ...e If the problem is occurred by the mistake or misuse of the customer we charge a repair cost even if it is within warranty period 2 This warranty card is valid within your country 3 Please keep this...