![Veltron DHOE-90 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/veltron/dhoe-90/dhoe-90_user-manual_3984870015.webp)
- 15 -
STOVES & CHIMNEYS
TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
IMMEDIATE
STOP JUST
AFTER IGNITION
“Lack of Fuel“ light ON?
Running out of fuel
Fill up the fuel.
Check if the fuel is Diesel
or kerosene
It may cause less per-
formance & trouble
Drain the existing fuel, an
d fi
ll with Diesel
or kerosene only.
Water or any other
impurities on fuel?
It may cause less per-
formance & trouble
Replace the fuel with good quality one.
Is
fl
ame sensor located
well?
In
diff
erent position, it
causes an error.
Place the sensor in original location.
Is
fl
ame sensor dirty?
Error because of soot
or dirt
Call after sales service agent.
Noise in fuel pump?
Excessive air in the
pump and nozzle.
Remove the air in the electric pump.
EXCESSIVE
SOOT IS
GENERATED
Check if the fuel is Diesel
or kerosene
It may cause less per-
formance & trouble
Drain the existing fuel, an
d fi
ll with Diesel
or kerosene only.
Water or any other
impurities on fuel?
It may cause less per-
formance & trouble
Replace the fuel with good quality one.
Is air suction valve
adjusted excessively or
too small?
Error on Temperature
sensor
Call after sales service agent.
Is tube clogged?
Smoke ma
y fl
ow
backward
Clean the tube by removing soot inside of
tube, or replace with new one.
NOISE IN
BURNER
Is Fuel
fi
lter st
uff
y?
Dirt
y fi
lter with
impurities and
contamination.
Clean or replace with new one
Noise in fuel pump?
Excessive air in the
pump and nozzle.
Remove the air in the electric pump.