Velp Scientifica ECO 8 Скачать руководство пользователя страница 5

Velp Scientifica 

– ECO8 Manual

 

 

10001328/A1

 

Temperature 
LED’s 

When the instrument is turned on, the four temperature 
LED’s will not be lit. This signals that a work cycle is not in 
progress. When a preset temperature is selected the 
corresponding LED will light. All of the LED’s will blink when 
the selected temperature is higher than the block 
temperature. 

Time LED’s 

When the instru

ment is turned on, the four time LED’s will not 

be lit. When a preset time is selected the corresponding LED 
will light. The LED blinks to signal that the preselected 
temperature has been reached and the time count has 
started. 

 
 
 

5.2  Power Interruptions 

The instrument will register a black out or a lack of power supply as a manual 
stop of the cycle. The work cycle will have to be restarted. 

 
 
 

5.3  Safety Features

 

The instrument is protected against overheating by a thermostat that turns off 
the power supply when the temperature exceeds 180°C. The temperature 
setting is continuously controlled by electronic equipment that stops 
thermoregulation if anomalous measurements are sensed.  
In the event of anomalous measurements, all temperature and time LED’s will 
start to blink and an acoustical warning signal will sound. 
 

Содержание ECO 8

Страница 1: ...be compatible with the temperature set on the unit 3 The instrument is equipped by a voltage changer accessibile on the rear panel which allows the connection to electric nets with 230 V or 115 V Bef...

Страница 2: ...and installation 4 5 Operation 4 5 1 Description of controls 4 5 2 Power interruptions 5 5 3 Safety features 5 6 Start of a cycle 6 7 Maintenance 6 7 1 Replacing fuses 6 8 Disposal 7 9 Accessories 7...

Страница 3: ...a microprocessor with a PID logic The temperature probe is a Pt100 probe which does not require any calibration because the electronics after each turning on performs a self calibration All this allow...

Страница 4: ...he key lower the programmed temperature to 150 120 100 or 70 C The selected temperature is shown by the lighting of the corresponding led It is possible to select different temperatures if the program...

Страница 5: ...t The LED blinks to signal that the preselected temperature has been reached and the time count has started 5 2 Power Interruptions The instrument will register a black out or a lack of power supply a...

Страница 6: ...will sound continuously for 5 seconds At this time the heating element and the LED s corresponding to time and temperature will turn off The instrument is now ready for a new work cycle If the selecte...

Страница 7: ...ture oscillations around the set point The Pt100 probe provides high precision and does not require calibration because the internal software performs a self calibration every time the instrument is t...

Страница 8: ...22 x n 1 Thermoregulation P I D microprocessor Precision 0 2 end of scale Temperature probe Pt 100 class A Probe calibration Automatic by software Heating block Temperature stability C 0 3 Temperature...

Страница 9: ...fica ECO8 Manual 10001328 A1 9 12 Electric scheme 1 5x20mm retarded fuse 3 15A 2 General lighted switch 3 Voltage changer electronic card 4 Safety thermostat 5 Electric resistance 6 Electronic card 7...

Страница 10: ...Velp Scientifica ECO8 Manual 10001328 A1 10 13 Suggestions Any suggests and advice would be greatly appreciated to enable us to constantly improve this instruction manual e mail service velp it...

Страница 11: ...t the product is in according with the following standards EN 61010 1 2001 EN 61326 1 2000 And satisfies the essential requirements of directives Machines directive 98 37 CEE Low voltage directive 73...

Страница 12: ...ur product Lines Environment C O D B O D B O D Sensor REFRIGERATED THERMOSTATS INCUBATORS JAR TEST METALS IN SLUDGES AND SEDIMENTS NEPHELOMETRIC TURBIDITY NITROGEN IN DIFFERENT FORMS PERFORMANCE OF AN...

Отзывы: