Velp Scientifica ECO 8 Скачать руководство пользователя страница 12

Velp Scientifica 

– ECO8 Manual

 

 

10001328/A1

 

Thanks for choosing a VELP’s product ! 

Since 1983 Velp offers to the professional in the field a range of sophisticated and reliable 
equipment  which  make  available  high  levels  of  know-how  and  operative  capacity  at 
competitive price.  
Velp  works  according  to  ISO  9001,  ISO14001  and  OHSAS  18001  Quality  System 
Certification. Instruments are built according to the International norms IEC 1010-1 and to 
the rules of CE mark. 
 
We present you our product Lines: 
 

Environment 

C.O.D. 
B.O.D. - B.O.D. Sensor 
REFRIGERATED THERMOSTATS 
INCUBATORS 
JAR TEST 
METALS IN SLUDGES AND SEDIMENTS 
NEPHELOMETRIC TURBIDITY 
NITROGEN IN DIFFERENT FORMS 
PERFORMANCE OF ANAEROBIC DIGESTERS 
PHENOLS 
LEACHABILITY TESTS 
 

Stirring 

MAGNETIC STIRRERS 
HEATING MAGNETIC STIRRERS 
MULTIPLACE MAGNETIC STIRRERS 
LIGHTED MAGNETIC STIRRERS 
HEATING PLATES 
VORTEX 
STIRRERS 
 

Food and feed 

DIGESTERS 
STEAM DISTILLING UNITS 
SCRUBBER 
CATALYST TABLETS 
NITROGEN-FREE WEIGHING BOATS 
EXTRACTORS FOR RAW FIBER 
EXTRACTORS FOR DIETARY FIBER 
EXTRACTORS FOR SELECTIVE EXTRACTION OF SOLUBLE PRODUCTS BY 
SOLVENTS (FOR FAT) 
 

Pumps 

PERISTALTIC PUMPS 
RECIRCULATING WATER VACUUM PUMP 

 

 

 

Содержание ECO 8

Страница 1: ...be compatible with the temperature set on the unit 3 The instrument is equipped by a voltage changer accessibile on the rear panel which allows the connection to electric nets with 230 V or 115 V Bef...

Страница 2: ...and installation 4 5 Operation 4 5 1 Description of controls 4 5 2 Power interruptions 5 5 3 Safety features 5 6 Start of a cycle 6 7 Maintenance 6 7 1 Replacing fuses 6 8 Disposal 7 9 Accessories 7...

Страница 3: ...a microprocessor with a PID logic The temperature probe is a Pt100 probe which does not require any calibration because the electronics after each turning on performs a self calibration All this allow...

Страница 4: ...he key lower the programmed temperature to 150 120 100 or 70 C The selected temperature is shown by the lighting of the corresponding led It is possible to select different temperatures if the program...

Страница 5: ...t The LED blinks to signal that the preselected temperature has been reached and the time count has started 5 2 Power Interruptions The instrument will register a black out or a lack of power supply a...

Страница 6: ...will sound continuously for 5 seconds At this time the heating element and the LED s corresponding to time and temperature will turn off The instrument is now ready for a new work cycle If the selecte...

Страница 7: ...ture oscillations around the set point The Pt100 probe provides high precision and does not require calibration because the internal software performs a self calibration every time the instrument is t...

Страница 8: ...22 x n 1 Thermoregulation P I D microprocessor Precision 0 2 end of scale Temperature probe Pt 100 class A Probe calibration Automatic by software Heating block Temperature stability C 0 3 Temperature...

Страница 9: ...fica ECO8 Manual 10001328 A1 9 12 Electric scheme 1 5x20mm retarded fuse 3 15A 2 General lighted switch 3 Voltage changer electronic card 4 Safety thermostat 5 Electric resistance 6 Electronic card 7...

Страница 10: ...Velp Scientifica ECO8 Manual 10001328 A1 10 13 Suggestions Any suggests and advice would be greatly appreciated to enable us to constantly improve this instruction manual e mail service velp it...

Страница 11: ...t the product is in according with the following standards EN 61010 1 2001 EN 61326 1 2000 And satisfies the essential requirements of directives Machines directive 98 37 CEE Low voltage directive 73...

Страница 12: ...ur product Lines Environment C O D B O D B O D Sensor REFRIGERATED THERMOSTATS INCUBATORS JAR TEST METALS IN SLUDGES AND SEDIMENTS NEPHELOMETRIC TURBIDITY NITROGEN IN DIFFERENT FORMS PERFORMANCE OF AN...

Отзывы: