Function
Description
Default
the strongest, the sensor provides the second-strongest return. If only one
return is detected, the two values will be identical.
Motor RPM
Sets the sensor’s internal spin rate. Valid values include the range from 300 to
1200 RPM, and 0. Setting it to 0 during active scanning will auto-disable the
sensor’s lasers, which re-enable automatically the next time RPM is set in the
valid non-zero range.
Set - Activates the changes.
600
FOV Start
Sets the start azimuth for a user-defined Field of View. Units: integer
degrees.
Set - Activates the changes.
0
FOV End
Sets the end azimuth for a user-defined Field of View. Units: integer degrees.
Set - Activates the changes.
359
PPS Qual-
ifier
Adjusts parameters that affect how PPS is used when synchronizing time
stamps to UTC.
Require GPS Receiver Valid: ON/OFF.
Require PPS Lock: ON/OFF.
Delay: Sets the qualification period (in seconds) for PPS.
Set - Activates the changes.
OFF
ON
5
GPS Qual-
ifier
Controls whether GPS Receiver Valid is required when synchronizing time
stamps to UTC.
Require GPS Receiver Valid: ON/OFF.
Set - Activates the changes.
OFF
Phase Lock
Used to synchronize the firing of two or more sensors. The offset is used to
set the azimuth at which the laser fires in conjunction with the PPS signal’s
rising edge. Requires a valid PPS signal.
Offset: Enter the offset as the desired degrees multiplied by 100. For
example, if the desired offset is 270º, enter 27000.
Set - Activates the changes.
OFF
0
Host (Destin-
ation)
IP Address (IPv4) to which the sensor transmits its data. By default it is set to
the broadcast address. If using one or more sensors in a network it must be
set to a non-broadcast IP address to avoid cross-loading.
Data Port — Port number for laser data packets.
Telemetry Port — Port number for position (telemetry) packets.
Set — Activates changes.
255.255.255.255
2368
8308
Network
(Sensor)
DHCP — When ON, the sensor obtains its IP address from a DHCP server on
its local network. When set to OFF, it uses the IP Address, Mask, and Gate-
way the user configures.
IPv4 Address — Sensor IP address as specified by the user.
Mask — Sensor subnet mask as specified by the user.
Gateway — Sensor gateway as specified by the user.
MAC Address - Sensor MAC address override.
Set — Activates changes.
OFF
192.168.1.201
255.255.255.0
192.168.1.1
Chapter 10 • Sensor Communication
69
DRAFT
Содержание VLS-128
Страница 1: ...VLS 128 User Manual 63 9483 Rev A DRAFT ...
Страница 63: ...Figure 9 8 VLS 128 Azimuth Offsets by Elevation Chapter 9 Sensor Data 63 DRAFT ...
Страница 102: ...C 3 VLS 128 Optical Keep Out Zone Figure C 3 VLS 128 Optical Keep Out Zone 86 0137 REV A 102 VLS 128 User Manual DRAFT ...
Страница 104: ...D 1 Interface Box Wiring Diagram Figure D 1 Interface Box Wiring Diagram 86 0107A 104 VLS 128 User Manual DRAFT ...
Страница 105: ...D 2 Interface Box Schematic Figure D 2 Interface Box Schematic 69 8230A Appendix D Wiring Diagrams 105 DRAFT ...