29
Option
10
11
12
13
14
15
16
17
Illustrated in Figure
7.15, 717 7.15, 7.17 7.17, 7.18 7.17, 7.18
7.17
7.17
7.17
7.17
Pipe
Penetration
through
Structure
Vent
Roof
Roof
Roof
Roof
Roof
Roof
Roof
Roof
Intake
Roof
Roof
Roof
Roof
Roof
Roof
Roof
Roof
Material
Vent
CPVC/
PVC
(Note 2)
CPVC/
PVC
(Note 2)
DuraVent
PolyPro
(Rigid)
DuraVent
PolyPro
(Rigid)
Selkirk
Polyflue
Selkirk
Polyflue
Centro-
therm
InnoFlue
SW
Centro-
therm
InnoFlue
SW
Intake
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
Nominal
Diameter
Vent
2"
3"
2"
3"
2"
3"
2"
3"
Intake
2"
3"
2"
3"
2"
3"
2"
3"
Min Equivalent Vent Length:
Model Sizes
85
30"
30"
30"
30"
30"
30"
30"
30"
110
30"
30"
30"
30"
30"
30"
30"
30"
155
Not
Permitted
30"
Not
Permitted
30"
Not
Permitted
30"
Not
Permitted
30"
205
30"
30"
30"
30"
270
30"
30"
30"
30"
Max Equivalent Vent Length (Note 1):
Model Sizes
85
60ft
135ft
60ft
135ft
60ft
135ft
60ft
135ft
110
60ft
135ft
60ft
135ft
60ft
135ft
60ft
135ft
155
Not
Permitted
135ft
Not
Permitted
135ft
Not
Permitted
135ft
Not
Permitted
135ft
205
135ft
135ft
135ft
135ft
270
135ft
135ft
135ft
135ft
Terminal Option H
(Fittings)
Vent
Coupling
w/Screen
Coupling
w/Screen
2PPS-12B
or
2PPS-36B
w/Screen
3PPS-12B
or
3PPS-36B
w/Screen
2PF-10UV
or
2PF-39UV
w/Screen
3PF-10UV
or
3PF-39UV
w/Screen
ISEP02 or
ISEP0239
w/Screen
ISEP03 or
ISEP0339
w/Screen
Intake 180 Elbow
w/Screen
180 Elbow
w/Screen
180 Elbow
w/Screen
180 Elbow
w/Screen
180 Elbow
w/Screen
180 Elbow
w/Screen
180 Elbow
w/Screen
180 Elbow
w/Screen
Terminal Option I
(Ipex FGV Concentric)
Ipex
196105
(Note 3)
Ipex
196006
(Note 3)
Not
Permitted
Not
Permitted
Not
Permitted
Not
Permitted
Not
Permitted
Not
Permitted
Terminal Option J
(Diversitech CVENT
Concentric)
CVENT-2 CVENT-3
Not
Permitted
Not
Permitted
Not
Permitted
Not
Permitted
Not
Permitted
Not
Permitted
Terminal Option K
(DuraVent Vertical
Concentric)
Not
Permitted
Not
Permitted
2PPS-VK
3PPS-VK
Not
Permitted
Not
Permitted
Not
Permitted
Not
Permitted
Notes:
1. Max vent lengths shown also apply to the intake. For example, Vent Option #1 may have up to 60ft of vent pipe and also up to 60 ft of
intake pipe.
2. At least 30" of CPVC pipe, and at least one CPVC elbow, must be installed between the boiler's vent connection and PVC pipe.
Downstream vent pipe can be PVC except as noted in text.
3. Ipex FGV Concentric Terminal available in various lengths and also CPVC (see text).
All vertical terminals require compatible roof flashing and storm collars.
VII. Venting
C. Design Requirements Unique to Vertical Venting Systems (continued)
Table 7.13a: Summary of Vertical Twin Pipe Venting Options
Содержание Raptor RPTR085
Страница 1: ...1...
Страница 13: ...13 Figure 5 1 Wall Layout Mounting Hole Location V Mounting The Boiler continued...
Страница 14: ...14 Figure 5 2 Boiler Mounting Bracket Installation Boiler Wall Mounting V Mounting The Boiler continued...
Страница 87: ...87 Figure 10 5 Internal Wiring Ladder Diagram X Wiring continued...
Страница 88: ...88 X Wiring continued...
Страница 97: ...97 Operating Instructions XI Start Up and Checkout continued...
Страница 142: ...142 XV Repair Parts continued 3A 3B 3C 3D 3F 3E 3G 3H 3O 3P 3Q 3R 3J 3K 3I 3M 3N 3L All Models...
Страница 148: ...148 XV Repair Parts continued 6D 6B 6A 6E 6I 6G 6L 6N 6H 6C 6K 6M 6C 6C 6J 6J 6F All Models...
Страница 172: ...172...