background image

VMB4PD 

2

 

Introduction 

 
This unique panel will let you control all of the output modules on the Velbus

®

 system. There is no need to 

remember the function of each button, just read the label next to it! 
The module also features programmable timing functions to automate daily or weekly button press actions. 
The infrared receiver will let you control the module at distance. 

 

Features

 

Four push buttons and one configuration push button. 
Up to 8 commands (2 groups of 4 commands each). 
The 2 command groups are directly callable through the configuration push button. 
Automatic switchover to the first group of commands after 15 seconds of inactivity. 
Push button debounce: 65ms. 
Possibility for each push button to react only when maintaining pressed (1s, 2s of 3s). 
Adjustable push button backlight: off – low dimming – high dimming – max. intensity. 
LED indication for each push button: slow, fast, very fast blinking or continuously on. 
 

Remote Control: 

Built-in IR receiver for use with the Velbus

®

 

Can be used with the VMBIRTS IR remote stick 
IR modulation: RECS80 
Transmitter/receiver range: ±10m 
 

LCD display: 

2 lines of 16 characters 
White backlight 
Adjustable backlight: off – low dimming – high dimming – max. intensity. 
Possibility to automatically adjust the backlight intensity (twice a day). 
Adjustable contrast through configuration menu. 
Labelling on the display for each command, 2 lines of 16 characters for each label 
 

Configuration: 

Adjustable display contrast and backlight. 
Adjustable push button backlight. 
Adjustable command reaction time (at once, 1, 2 or 3 seconds) 
Command labelling. 
Module address configuration (256 possible addresses). 
Clock configuration. 
Mode configuration (command panel only, command panel with timer or command panel with timer for the 
2

nd

 group of commands). 

Input and modification of the timer program steps. 
Timer activation or deactivation for a specific push button. 
Configuration menu will automatically close after 25 seconds of inactivity. 
 

Clock: 

Built-in clock with day display. 
Setting one clock will adjust all other clocks on the Velbus

® 

system. 

Possibility to configure one clock as main clock – all other clocks will run right. 

 
Timer: 

Programmable timer functions for push button command automation. 
Up to 20 program steps. 
Each program step can automate up to 8 commands. 
 

Push Button and Timer Module

 

for Velbus

®

 System

 

VMB4PD

 

Содержание Velbus VMB4PD

Страница 1: ...VMB4PD 1 VMB4PD Push Button and Timer Module for Velbus System...

Страница 2: ...range 10m LCD display 2 lines of 16 characters White backlight Adjustable backlight off low dimming high dimming max intensity Possibility to automatically adjust the backlight intensity twice a day A...

Страница 3: ...er Area Network Short circuit proof towards negative or positive of power Bus error indication 2 x short flash of the indication LED Self restoring after 25 seconds in case of a bus error Possibility...

Страница 4: ...nd the polarity H L BUS 12V VMB4PD L H 12V BUS TWISTED PAIR 0 5mm 2 Connect a 9V battery via the included cable if you desire to power the clock in case of a power failure 12V power supply L H Velbus...

Страница 5: ...jumper Remove the jumper in all other cases If different cable wiring topologies tree star loop are used place a jumper on the end module of the longest cable only NOT on each end point Velbus transm...

Страница 6: ...utton has been pressed maintained pressed or released Other modules relay modules blind control modules dimmers connected to the Velbus will react and answer by resending a command message to the push...

Страница 7: ...ht push button to activate the display menu Press the configuration button to display the next configuration menu Press the upper left push button to activate the mode menu Press the upper right push...

Страница 8: ...ule even with a power failure The first configuration menu shows menus Prog and Timer on off when the timer is activated The module will automatically quit the configuration mode after 30 seconds of i...

Страница 9: ...guration button pressed for 8 seconds to display the contrast mode The display contrast may be set too low if experiencing a blank display Hold the configuration button pressed for 8 seconds to switch...

Страница 10: ...ences This is useful when trying to locate the buttons in a completely dark room 1 Hold the configuration button pressed for 4 seconds to display the configuration menu 2 Press the upper right button...

Страница 11: ...imer 9 Enter the first time and intensity using the upper buttons Enter the second time and intensity using the lower buttons In the example above the backlight will be set at full intensity at 08h00...

Страница 12: ...he configuration button pressed for 4 seconds to display the configuration menu 2 Press the upper left button to display the clock menu 3 Press the upper right button to set the day 4 Press the lower...

Страница 13: ...he display contrast may be set too low if experiencing a blank display Hold the configuration button pressed for 8 seconds to switch the module to the configuration menu which allows modifying contras...

Страница 14: ...pressed for 4 seconds to display the configuration menu 2 Press the upper left button to display the clock menu 3 Press the configuration button again to display the next clock menu 4 Press the upper...

Страница 15: ...onfiguration menu 3 Press the upper right button to display the address menu 4 Press the upper left button to select the left address digit blinking digit Press the upper right button to select the ri...

Страница 16: ...Press the lower right button to display the label editor 4 Move the cursor to the left or to the right using the two upper push buttons Select the character using the two lower push buttons Press the...

Страница 17: ...lowing characters can be chosen from 0 P p 1 A Q a q 2 B R b r 3 C S c s 4 D T d t 5 E U e u 6 F V f v 7 G W g w 8 H X h x 9 I Y i y J Z j z K k L l M m N n O _ o Hold a button pressed to scroll Scrol...

Страница 18: ...lay the next configuration menu 3 Press the lower left push button to display the reaction time menu 4 Press the lower buttons to set a reaction time of 0 1 2 or 3 seconds for the displayed command Pr...

Страница 19: ...reaction time of 0 1 2 or 3 seconds for the displayed command 8 Press the configuration button to quit the reaction time menu Remarks The module will automatically quit the reaction time menu after 3...

Страница 20: ...on menu 2 Press the configuration button again to display the configuration menu 3 Press the upper left button to display the mode menu 4 Press the upper right button to set the user mode Following us...

Страница 21: ...ation menu 2 Press the lower left button to display the program menu 3 The display shows the first program step program number time and a view of the automated commands Remark The program indications...

Страница 22: ...the lower right button to display the previous program step 6 Press the lower left button to modify the displayed program step Next program step Quit program menu Previous program step Quit program m...

Страница 23: ...uted every Saturday and Sunday Mo Fr Program step is executed every day except on Saturday and Sunday Mo Sa Program step is executed every day except on Sunday Mo Su Program step is executed every day...

Страница 24: ...y on the time day hour minutes programmed and memorized into the program step 11 Press the configuration button to display the next program step setting menu 12 Press the lower buttons to add or to re...

Страница 25: ...button to display the next program step setting menu 16 Press the lower buttons to add or to remove the displayed command to or from the program step Label command 5 Label command 6 Add or remove comm...

Страница 26: ...1 will be executed every Monday morning at 08h30 commands 3 5 and 8 will be activated briefly Program indications for commands 1 through 4 disappear if the timer function has been activated for the se...

Страница 27: ...e command will not be used in the timer program the timer program for a particular command will not be executed the timer program for a particular command is activated The timer indications for comman...

Страница 28: ...1 and 2 are not used in the program Go to section 10 if commands 1 through 4 are not used in the program Go to section 12 if commands 1 through 6 are not used in the program 6 Press the lower buttons...

Страница 29: ...enter the next timer activation menu The module exits the timer activation menu if commands 5 through 8 are not used in the program go to section 14 Go to section 12 if commands 5 and 6 are not used...

Страница 30: ...he module displays the current time and an overview of the active timer programs in this example the timer program for commands 1 3 5 and 8 will be executed Press the configuration button to display t...

Страница 31: ...will not be executed the timer program for a particular command is activated Timer indicators for commands 1 through 4 disappear if the timer function is activated for the seconds set of commands onl...

Страница 32: ...k will make the module display the corresponding labels Activating commands 5 through 8 on the stick will make the module display the corresponding labels The module will automatically return to the d...

Страница 33: ...be set at its maximum Selection of blank characters during labelling Press the configuration button a couple of times until a blinking cursor is displayed in the upper left corner Enter your label usi...

Страница 34: ...VMB4PD 34...

Страница 35: ...VMB4PD 35...