10. SAFETY PRECAUTIONS 
 
In case of trouble with the AC output, e.g. short-circuit, overload, etc… the 
protection circuit will automatically cut off the output. 
In such cases : 

(A)  switch off the power at once 

 

(B)  disconnect all devices 

 

(C)  check the devices for damage 

 

(D)  connect the devices again as soon as all problems, if 

any, have been solved 

 
When the device has been used for a prolonged period of time, the AC output 
may suddenly be cut off even though the battery voltage is still very strong. This 
may be caused by high temperatures. If this happens, please proceed as follows : 
 

(A)  switch off the inverter at once 

 

(B)  disconnect some of the appliances or wait until the inverter cools off 

 

(C)  switch the inverter back on 

 
Always keep the inverter in an environment which is : 
(A) well-ventilated 
(B)  not exposed to direct sunlight or any other heat source 
(C)  inaccessible to children 
(D)  safe from water/moisture, oil or grease 
(E)  safe from any flammable substance 
 
Connecting the inverter in the wrong way will void the warranty. 
 
Do not operate this device with wet hands and do not open the housing in order to 
avoid the risk of electroshocks. 
 
Do not establish a direct connection between this device and another AC power 
source. The ensuing damage would void the warranty. 
 
Do not use this device with appliances of more than 150W. 
 
This device cannot be used with inductive or capacitive loads, e.g. a laptop. 
Disturbances may occur when using the PI150S with certain television sets. 
Consult the manual of your TV if this problem should occur. 
 

Содержание PI150S

Страница 1: ...ill WILL DAMAGE IT AND AUTOMATICALLY VOID THE WARRANTY HET TOESTEL ZAL WORDEN BESCHADIGD INDIEN U HET OVERBELAST OF ER EEN INDUCTIEVE BELASTING vb koelkast boormachine ventilator OP AANSLUIT DE GARANTIE VERVALT DAN AUTOMATISCH LA SURCHARGE DE L APPAREIL OU LA CONNEXION D UNE CHARGE INDUCTIVE p ex ventilateur réfrigérateur perceuse ENDOMMAGERONT L APPAREIL ET LA GARANTIE SERA INVALIDEE AUTOMATIQUEM...

Страница 2: ...ce the inverter is connected to If the buzzer while you are operating the PI150S this indicates that the battery voltage is very low and that the inverter will be disconnected in 5 minutes 4 FUSE Please check the fuse in the housing and the one in the cigarette plug if the power LED is not lit during operation Replace a blown fuse with an identical one FUSE 15A MAX power switch AC output socket po...

Страница 3: ...s will leave your vehicle s battery with 10 5VDC enabling you to restart your engine and resume operation of the inverter It also eliminates the possibility of ending up with a dead battery Let your engine run for 10 to 20 minutes after every 2 3 hours of using the AC inverter in order to avoid excessive discharging of the battery This allows your vehicle s battery to recharge Please remember to d...

Страница 4: ...t in reduced power 8 MEASURING AC VOLTAGES The output wave of the AC inverter is a PURE SINEWAVE If you choose to measure the AC output voltage you must use an AUTHENTIC RMS VOLT METER Using any other type of voltage measuring device will result in an AC voltage reading 20 to 30V lower than the rated value The reading will only be accurate when using an authentic RMS voltmeter 9 VENTILATION IMPORT...

Страница 5: ...il the inverter cools off C switch the inverter back on Always keep the inverter in an environment which is A well ventilated B not exposed to direct sunlight or any other heat source C inaccessible to children D safe from water moisture oil or grease E safe from any flammable substance Connecting the inverter in the wrong way will void the warranty Do not operate this device with wet hands and do...

Страница 6: ...er 150W Output Frequency 50Hz Output Wave pure sine wave Efficiency full load 90 Max Efficiency load 1 3 95 Total Harmonic Distortion 4 No Load Power Consumption 4W Battery Low Alarm 10 5 0 5VDC Battery Low Shutdown 10 0 5VDC Overheating Protection 55 5 C Dimensions 205 x 99 x 62mm Weight 0 92kg ...

Отзывы: