background image

 

Menu options 
 

File Menu   

 
Open Image   

 Opens an image file and displays it on the screen.   
   

Open Data   

 Opens and displays the waveform data saved in text format using the Save Data or AutoSave Data option.   
   

Save Image   

 Saves the image to a file in PNG or in Windows Bitmap (BMP) format.   
   

Save Data   

 Saves the waveform in text format. only the portion of the data displayed on the screen is saved.   
 

AutoSave Data   

 Saves all next screens of data in text format to a file.     
 The AutoSave function will be activated after the Run button is pressed.     
 The AutoSave function will be finished after the Run button is pressed again.     
 Note: Every screen saved takes about 90kB of disk space   
   

Print   

 Prints the image.     
 You can edit the image caption.     
     
  

Print Setup   

 Selects a printer and sets printer options before printing. The available options depend on the printer you 
select.   
   

Exit   

 Terminates the program. 
 

Restore Default Settings &

 Exit   

 Use this option to restore all values to their default factory settings.     
 The calibration values will be reset.     
 Use this option if the recorder calibration fails repeatedly.     
 Note: Software reinstallation does not reset the recorder settings - you have to use this menu option to 
restore default settings. 
 













 
 

Options Menu   

 

Colors   

 Select the color for various items on the waveform display.       

Содержание PCRU01

Страница 1: ...diagnostic led 3 Signal input 3 Readout screens 4 Analog screen 4 Digital screen 4 Software controls 5 Analog readout 5 Voltage range 5 ON Checkbox 5 Time div 5 Run 5 Single 5 X position scrollbar 5...

Страница 2: ...DVM from 20 ms to 1000 sec per division storage and recall of screens full colour or data automatic recording option for long recordings on screen markers for time and voltage DLL included for your o...

Страница 3: ...components Costs and risks connected to the transport removal or placement of the product or any other costs directly or indirectly connected to the repair will not be reimbursed by VELLEMAN Ltd VELLE...

Страница 4: ...eadout screens Analog screen Using this screen the 4 channels can be viewed simultaneously as a trace on the screen Digital screen Powerful feature which allows digital visualisation of the measuremen...

Страница 5: ...e beam to sweep one major division on the screen Selection of TIME DIV is possible to zoom in on the frozen waveform display RUN 4 Selects recurrent display update mode RUN Pressing the button again f...

Страница 6: ...Momentary voltage Momentary voltage 1 Shows the momentary measurement readout of the voltage Max Min voltage storage 2 When this option is selected the signals max min voltage values and the date tim...

Страница 7: ...function will be finished after the Run button is pressed again Note Every screen saved takes about 90kB of disk space Print Prints the image You can edit the image caption Print Setup Selects a prin...

Страница 8: ...ge Markers dV dt The time difference between the two markers is displayed Two horizontal markers for measuring voltage DVM display Displays the digital screen recorder logger Bright Grid Brightens the...

Страница 9: ...use a deviation in the time measurement To ensure the precision of the time measurement at short timebase Use a fast computer Do not run other applications when recording Use highest possible processo...

Отзывы: