20. HOOK-UP AND USE
Power supply :
•
Batteries : 4 x 1.5V AAA (use included battery holder)
Idle power consumption : 15µA max.
Record power consuption : 26mA
Playback : 50mA max.
•
Transformer : secundary : 9 to 12VAC
Idle power consumption : 7mA
Record power consumption : 40mA
Playback : 75mA max.
Hook-up of one unit :
•
Mount wire jumpers JR & JE
•
For message auto-repeat, connect RPT to STRT (by means of a switch)
•
RPT and STRT must not be connected during message recording.
Hook-up of two or more units :
•
Mount JR and JE on the last module
•
Mount JC on the other module(s)
•
For message auto-repeat, connect RPT of the last module with STRT of
the first module.
•
During replay, a ‘click’ sound is heard at switchover between two units.
•
If 5 or more units are put in cascade, the voltage regulator (VR1) of the
first unit needs to be cooled with a small heatsink.
Signal input :
•
Microphone :
Mount wire jumper JM on the first module.
•
Line input :
Enter the audio signal between AIN and GND
Max input level : 25mV rms
Signal output :
•
Loudspeaker :
Connect an 8 ohm loudspeaker between SP- and SP+ of the first module.