background image

DVM805 

- 1 -

 

VELLEMAN 

DVM805 – DIGITAL SOUND LEVEL METER 

 

1. Introduction 

 

To all residents of the European Union 

Important environmental information about this product 

 
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. 
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialised company for recycling. 
This device should be returned to your distributor or to a local recycling service. 
Respect the local environmental rules. 

If in doubt, contact your local waste disposal authorities. 

 
Thank you for buying the 

DVM805

! Use it only as specified in this manual to avoid erroneous performance. 

 
 

2. Specifications 

 
Max. altitude 

2000 m 

Applicable standard 

IEC651 type 2, ANSI S1.4 type 2 

Frequency range 

31.5Hz ~ 8 KHz 

Measuring level range 

35 ~ 130dB (Lo: 35-100 dB; Hi: 65-130dB) 

Frequency weighting 

A/C 

Microphone 

½" electret condenser microphone 

Calibration 

electrical calibration with the internal oscillator (1 kHz sine wave) 

Display 

3 ½ digit LCD 

Resolution 

0.1dB 

Time weighting 

fast (125ms) or slow (1s) 

Accuracy 

± 1.5dB (under reference conditions) 

Overrange indication 

“OVER” is displayed 

Auto power-off 

after 15 minutes of inactivity 

Power supply 

one 9V-battery (NEDA 1604 or 6F22) 

Battery life 

± 50hrs (alkaline battery) 

Low-Battery indication 

“BAT” is displayed  

Operating temperature 

0~40°C (32~104°F) with 10~90% RH 

Storage temperature 

-10 to +60°C (14 to 140°F) with 10~75% RH 

Dimensions (H x W x D) 

210 x 55 x 32 mm 

Weight 

230g (incl. battery) 

 
 

3. Front Panel Description 

 
1.  Wind cap: in wind speeds of >10m/s, put this cap over the microphone 
2.  ½" electret condenser microphone 
3.  Display: 3 ½-digit LCD with MAX HOLD, DATA HOLD, Lo, Hi, A, C, BAT, S, F, dB, and 

OVER indication 

4.  POWER ON/OFF button 
5.  Backlight button 
6.  A/C weighting button (A = general; C = low frequencies) 
7.  F/S button: to select slow or fast response 
8.  Low/Hi button: to select the higher or lower measuring ranges 
9.  MAX/HOLD button: 
10. Battery cover for 9V battery at the back of the meter

Содержание DVM805

Страница 1: ...hone electret condenser microphone Calibration electrical calibration with the internal oscillator 1 kHz sine wave Display 3 digit LCD Resolution 0 1dB Time weighting fast 125ms or slow 1s Accuracy 1...

Страница 2: ...t toestel of de verpakking geeft aan dat als het na zijn levenscyclus wordt weggeworpen dit toestel schade kan toebrengen aan het milieu Gooi dit toestel en eventuele batterijen niet bij het gewone hu...

Страница 3: ...ow dB of snel fast dB te selecteren 5 Zowel in A als in C weging heeft het toestel een frequentiebereik van 30Hz 10KHz 6 De snelle respons is ideaal om korte geluidssignalen en hoge waarden te meten 7...

Страница 4: ...F avec 10 75 RH Dimensions 210 x 55 x 32 mm Poids 230g pile incluse 3 Description panneau frontal 1 Bonnette anti vent utilisez bonnette anti vent en cas de rafales de 10m s 2 microphone type condensa...

Страница 5: ...ne dudas contacte con las autoridades locales para residuos Gracias por haber comprado el DVM805 Utilice este aparato s lo para las aplicaciones descritas en este manual para evitar un uso incorrecto...

Страница 6: ...7 El nivel sonoro se visualiza en la pantalla LCD Nota r fagas de m s de 10m seg podr an influenciar las mediciones Utilice la pantalla cortavientos incl si fuera necesario 5 Reemplazar la pila Reempl...

Страница 7: ...B und OVER Anzeige 4 EIN AUS Taste 5 Taste Hintergrundbeleuchtung 6 A C Bewertung A allgemein C niedrige Frequenzen 7 F S Taste um eine schnelle oder langsame Ansprechzeit zu w hlen 8 Low Hi Taste um...

Отзывы: