Velleman DVM1090 Скачать руководство пользователя страница 6

DVM1090                                                                                                                                                                  GB 

5

4.2.5. Resistance 

 

Range Resolution 

Accuracy 

200

 0.1

 

±1.0% of rdg ± 3 digits 

2k

 

1

 

±1.0% of rdg ± 1 digits 

20k

 10

 

±1.0% of rdg ± 1 digits 

200k

 100

 

±1.0% of rdg ± 1 digits 

2M

 1k

 

±1.0% of rdg ± 1 digits 

20M

 10k

 

±1.0% of rdg ± 5 digits 

 
Open-Circuit Voltage  :  ±700mV 

Overload Protection  :  250V DC or rms 
 
 

4.2.6. Capacitance 

 

Range Resolution 

Accuracy 

2nF 

1pF 

±4.0% of rdg ± 8 digits 

20nF 

10nF 

±4.0% of rdg ± 3 digits 

200nF 

0.1nF 

±4.0% of rdg ± 3 digits 

2µF 

1nF 

±4.0% of rdg ± 3 digits 

20µF 

10nF 

±4.0% of rdg ± 5 digits 

 
Overload Protection  :  F1 : F 200mA/250V fuse (quick-acting, max. resistance 2

 
 

4.2.7. Inductance 

 

 

Range Resolution 

Accuracy 

2mH 

0.001mH 

±4.0% of rdg ± 8 digits 

20mH 

0.01mH 

±4.0% of rdg ± 3 digits 

200mH 

0.1mH 

±4.0% of rdg ± 3 digits 

2H 

1mH 

±4.0% of rdg ± 3 digits 

20H 

10mH 

±4.0% of rdg ± 5 digits 

 
Overload Protection  :  F1 : F 200mA/250V fuse (quick-acting, max. resistance 2

Tested Inductance  :  Q 

 10, internal impedance 

 1k

 

 
 

4.2.8. Temperature 

 

Range Resolution 

Accuracy 

-20 to 0°C 

1°C 

±5.0% of rdg + 4 digits 

0 to 400°C 

1°C 

±1.0% of rdg ± 3 digits 

401 to 1000°C 

1°C 

±2.0% of rdg ± 3 digits 

 
Overload Protection  :  F1 : F 200mA/250V fuse (quick-acting, max. resistance 2

Содержание DVM1090

Страница 1: ...DVM1090 DIGITAL THERMOMETER DIGITALE THERMOMETER THERMOMETRE NUMERIQUE DIGITALES THERMOMETER MULT METRO DIGITAL User Manual Gebruikershandleiding Manuel d utilisation Gebrauchsanleitung Manual...

Страница 2: ...erminals when the meter is connected to a circuit Place the range selector switch in the highest position if the value to be measured is unknown beforehand Do not measure voltages 1000V above earth gr...

Страница 3: ...F position when the device is not being used Remove the batteries to keep them from leaking if the device is to be stored for a prolonged period of time 3 Front Panel Description 1 LCD display 2 L C b...

Страница 4: ...ction F 200mA 250V quick acting max resistance 2 F 10A 250V quick acting Power Supply 9V battery e g 6F22 Operating Temperature 0 C to 40 C 32 to 104 F Storage Temperature 10 C to 50 C 10 to 122 F Dim...

Страница 5: ...2 3 DC Current Range Resolution Accuracy 2mA 1 A 1 0 of rdg 3 digits 20mA 10 A 1 0 of rdg 3 digits 200mA 100 A 1 5 of rdg 5 digits 10A 10mA 2 0 of rdg 10 digits Overload Protection F1 F 200mA 250V fu...

Страница 6: ...gits 20 F 10nF 4 0 of rdg 5 digits Overload Protection F1 F 200mA 250V fuse quick acting max resistance 2 4 2 7 Inductance Range Resolution Accuracy 2mH 0 001mH 4 0 of rdg 8 digits 20mH 0 01mH 4 0 of...

Страница 7: ...ES from the display 4 2 11 Diode Range Resolution Function 1mV Read the diode s approximate forward voltage value from the display Forward DC Current 1mA Reversed DC Voltage 2 8V Overload Protection 2...

Страница 8: ...ressed in for AC voltage and AC current measurements 5 4 Selecting L or C Put the button in the pressed down position for inductance and capacitance measurements The component can now be tested Put th...

Страница 9: ...splays the overrange indication 1 if the measured value is too high for the range you are using Select a higher range Place the range selector in the highest position if the value to be measured is un...

Страница 10: ...make sure that all capacitors are fully discharged before measuring the in circuit resistance 1 Connect the black test lead with the COM jack and the red test lead with the jack 2 Select the desired r...

Страница 11: ...on socket included with the COM V A sockets Insert the inductor s pins in the and connectors of the multifunction socket REMARKS Keep in mind that precise inductance measurements are impossible in clo...

Страница 12: ...suring the circuit s continuity 1 Connect the black test lead with the COM jack and the red test lead with the jack 2 Place the range switch in the desired range position 3 Connect the test leads with...

Страница 13: ...est leads before replacing the fuse in order to avoid electroshocks In order to avoid unnecessary fire risks you should only use fuses with the following ratings F1 F 200mA 250mV quick acting resistan...

Отзывы: