DVM1090
DIGITAL THERMOMETER DIGITALE THERMOMETER THERMOMETRE NUMERIQUE DIGITALES THERMOMETER MULTÍMETRO DIGITAL
User Manual Gebruikershandleiding Manuel d’utilisation Gebrauchsanleitung Manual
Страница 1: ...DVM1090 DIGITAL THERMOMETER DIGITALE THERMOMETER THERMOMETRE NUMERIQUE DIGITALES THERMOMETER MULT METRO DIGITAL User Manual Gebruikershandleiding Manuel d utilisation Gebrauchsanleitung Manual...
Страница 2: ...erminals when the meter is connected to a circuit Place the range selector switch in the highest position if the value to be measured is unknown beforehand Do not measure voltages 1000V above earth gr...
Страница 3: ...F position when the device is not being used Remove the batteries to keep them from leaking if the device is to be stored for a prolonged period of time 3 Front Panel Description 1 LCD display 2 L C b...
Страница 4: ...ction F 200mA 250V quick acting max resistance 2 F 10A 250V quick acting Power Supply 9V battery e g 6F22 Operating Temperature 0 C to 40 C 32 to 104 F Storage Temperature 10 C to 50 C 10 to 122 F Dim...
Страница 5: ...2 3 DC Current Range Resolution Accuracy 2mA 1 A 1 0 of rdg 3 digits 20mA 10 A 1 0 of rdg 3 digits 200mA 100 A 1 5 of rdg 5 digits 10A 10mA 2 0 of rdg 10 digits Overload Protection F1 F 200mA 250V fu...
Страница 6: ...gits 20 F 10nF 4 0 of rdg 5 digits Overload Protection F1 F 200mA 250V fuse quick acting max resistance 2 4 2 7 Inductance Range Resolution Accuracy 2mH 0 001mH 4 0 of rdg 8 digits 20mH 0 01mH 4 0 of...
Страница 7: ...ES from the display 4 2 11 Diode Range Resolution Function 1mV Read the diode s approximate forward voltage value from the display Forward DC Current 1mA Reversed DC Voltage 2 8V Overload Protection 2...
Страница 8: ...ressed in for AC voltage and AC current measurements 5 4 Selecting L or C Put the button in the pressed down position for inductance and capacitance measurements The component can now be tested Put th...
Страница 9: ...splays the overrange indication 1 if the measured value is too high for the range you are using Select a higher range Place the range selector in the highest position if the value to be measured is un...
Страница 10: ...make sure that all capacitors are fully discharged before measuring the in circuit resistance 1 Connect the black test lead with the COM jack and the red test lead with the jack 2 Select the desired r...
Страница 11: ...on socket included with the COM V A sockets Insert the inductor s pins in the and connectors of the multifunction socket REMARKS Keep in mind that precise inductance measurements are impossible in clo...
Страница 12: ...suring the circuit s continuity 1 Connect the black test lead with the COM jack and the red test lead with the jack 2 Place the range switch in the desired range position 3 Connect the test leads with...
Страница 13: ...est leads before replacing the fuse in order to avoid electroshocks In order to avoid unnecessary fire risks you should only use fuses with the following ratings F1 F 200mA 250mV quick acting resistan...