DEM104
V. 01
–
07/05/2015
5
©Velleman nv
7.
Operation
7.1
General Operation
1.
Shortly press the on-off button to switch on the meter.
2.
Aim the IR sensor towards the object to be measured.
3.
Hold the on-off button pressed. The temperature will be
displayed on the LCD display.
4.
Release the on-off button to freeze the reading.
5.
The meter will automatically switch off after 15 seconds of
inactivity.
Remarks:
The temperature
of a shiny or polished metal surface
through a transparent surface such as glass
of an object covered with frost, grime, oil
cannot be measured.
7.2
°C or °F Selection
1.
Open the battery compartment using an appropriate
screwdriver. Remove the clip.
2.
Shortly press the °C/°F button to change the measurement unit.
3.
Close the battery compartment.
8.
Cleaning and Maintenance
Wipe the device regularly with a moist, lint-free cloth. Do not use
alcohol or solvents. DO NOT submerge the device in any liquid.
Store the meter in a dry place away from humidity and vibrations.
Remove the batteries when the meter is to be stored for long
periods of time.
9.
Technical Specifications
measurement range
-50° C to 260° C (-58° F to 500° F)
target ratio
1:1
emissivity
0.95 fixed
operating temperature
0 ~ 50° C (32 ~ 122° F)
storage temperature
-20° C to 60° C (-4° F to 140° F)
accuracy
± 2 % ± 2° C / 4° F
resolution
0.1° C / 0.1° F
response time
< 500 ms
Содержание DEM104
Страница 2: ...DEM104 V 01 07 05 2015 2 Velleman nv...