DCM120
V. 04
–
25/02/2020
10
©Velleman nv
9.4
RESISTANCE
Do not conduct resistance measurements on live circuits
range
resolution
accuracy
200
Ω
0.1
Ω
± (1.0 % + 10)
2 k
Ω
0.001 k
Ω
± (0.8 % + 5)
20 k
Ω
0.01 k
Ω
200 k
Ω
0.1 k
Ω
2 M
Ω
0.001 M
Ω
20 M
Ω
0.01 M
Ω
± (2.0 % + 10)
Overload protection: 250 V DC or AC rms
9.5
DIODE + AUDIBLE CONTINUITY
Do not conduct diode and continuity measurements on
live circuits
range
function
displays approx. forward voltage of the diode, reverse
shows OL
built-in buzzer sounds if resistance < 30
Ω
Overload protection: 250 V DC or AC rms
9.6
TEMPERATURE
range
-20 °C - 1000 °C
resolution
1 °C
accuracy
-20 °C - 0 °C
± (5.0 % + 4)
0 °C - 400 °C
± (2.0 % + 3)
400 °C - 1000 °C
± (3.0 % + 3)
range
0 °F - 1800 °F
resolution
1 °F
accuracy
0 °F - 50 °F
± (5.0 % + 4)
50 °F - 750 °F
± (2.0 % + 3)
750 °F - 1800 °F
± (3.0 % + 3)
Overload protection: 250 V DC or AC rms
Содержание DCM120