USER MANUAL

SAFETY INFORMATION

Overvoltage / installation categories

CAT II: A CAT II-rated meter is suitable for measurements on mono-phase appliances that are connected to the 

mains by means of a plug and circuits in a normal domestic environment. E.g. household appliances, portable 

tools…  

Provided that the circuit is at least 10m apart from a CAT III- or 20m apart from a CAT IV-environment. 

Pollution degree

 

Pollution degree 2: Only nonconductive pollution occurs.  

Occasionally, temporary conductivity caused by condensation is to be expected. (home and office environments 

fall under this category).

DURING USE

•  Never exceed the limit values for protection. These values are listed in the specifications.

• 

Do not touch unused terminals when the unit is linked to a circuit which is being tested.

• 

When carrying out measurements on a TV set or switching power circuits, always remember that the meter 

may be damaged by high amplitude voltage pulses at test points.

•  Always be careful when working with voltages above 60Vdc or 30Vac rms. Keep your fingers behind the 

probe barriers at all times during measurement.

• 

Use a measuring probe with an insulated connector when measuring voltages exceeding 30V.

• 

For X10 probe: match the frequency response to the oscilloscope input by adjusting the compensation trim-

mer on the probe, see probe manual.

PROTECTIVE POUCH FOR VELLEMAN INSTRUMENTS

 

HPSP1

Содержание HPS140MK2

Страница 1: ...W W W V E L L E M A N P R O J E C T S E U USER MANUAL HANDHELD OSCILLOSCOPE HPS140MK2...

Страница 2: ...ities about waste disposal rules Safety General rules concerning safe To ensure your safety please observe these safety measures In no way these are complete As safety requirements vary please check w...

Страница 3: ...this category DURING USE Never exceed the limit values for protection These values are listed in the specifications Do not touch unused terminals when the unit is linked to a circuit which is being te...

Страница 4: ...HPS140MK2 HPSPR1 X10 measuring probe HPSP1 Velleman Instruments pouch Features Specifications input range 1mV to 20V division in 14 steps input coupling DC AC and GND time base 250ns to 1h per divisi...

Страница 5: ...ode can be used for most repetitive signals Set the input coupling to DC if very low frequencies or DC voltages are measured see further 1 signal and menu display 2 menu button menu selection up 3 up...

Страница 6: ...e voltage per division Adapt the scope readout to the probe setting x1 or x10 Time base More or less signal cycles will be visible by modifying the time per division Select the desired voltage readout...

Страница 7: ...will switch between Volt V Time t and Input coupling selection Move the signal vertically over the display Y scroll bar Increase or decrease the contrast until the desired contrast is reached Select C...

Страница 8: ...d to call the extended menu 3 Press the menu or hold buttons briefly to scroll in the menu 4 Use the up or down buttons to change or selected an item Using the short menu you can move the signal marke...

Страница 9: ...9 HPS140MK2 USER MANUAL USING THE COMPONENT TESTER In order to use the component tester an optional adaptor HPS141 is required Full manual coming soon...

Страница 10: ...VELLEMAN nv Legen Heirweg 33 Gavere Belgium vellemanprojects com VellemanProjects Vel_Projects ORDERCODE HPS140MK2 REVISION HHPS140MK2...

Отзывы: