3.

 

INSTALLATION 

INSTRUCTIONS 

3.1

 

Choosing Proper Location for the Air 

Conditioner 

  

Make sure the roof is designed to support the 
weight of the unit and the weight of two installers. 
 

  

Electrical shock hazard! Make sure to disconnect all 
power supplies to the vehicle including battery, 
generator, and shore power prior to installation. 
 

 

The unit can fit over an existing 14-1/4 by 

14-1/4 roof opening.  For other locations, make 
sure the slope of the select location is less than 15 

degrees and leave a clearance of at least 10” from 

the edge of the roof. Refer to specifications for the 
dimension of the unit. 

 

After the location has been selected, check for 

obstructions in the area where the unit will be 
installed.  

 

Check the inside of the camper for decor panel 

obstructions. Allow 6” clearance from all edges of 

the opening. 

 

Route the 6AWG power cable to the roof 

opening. Leave at least six inches of slack. For 
cables longer than 10ft, refer to NEC (National 
Electric Code) for proper sizing of wire (12V 60A). 
 

4.2 Attach the Sealing gasket to the Roof 
Opening  
 

 

 

Clean the surface between the unit and the 

roof where the sealing gasket will be installed.

 

 

Apply sealant to the bottom of the sealing 

gasket.

 

 

Place the sealing gasket on the roof opening. 

 

 

For better sealing, apply sealant to the edge 

where the sealing gasket contacts the roof.

 

 

At the shown locations and other places if 

needed, stick the foam pieces between the unit 
and the roof to better support the unit

 

 

 
4.3 Place the Unit in the Roof Opening 

 

Grasp the bottom two sides of the unit, lift it, 

and place it into the roof opening.

 

 

Pull out the power cable. 

 
4.4 Secure the Unit to the Mounting 
Brackets 

 

 

Choose the proper length of M8 tie rods based 

on roof thickness. 

 

 

Insert the tie rods in the shown mounting 

holes (#10). 

 

 

Secure the tie rods with nuts. 

 

Содержание R2000

Страница 1: ...1 Page ...

Страница 2: ...TION 3 1 1 Understand Signal Words 3 1 2 General Safety Message 3 2 SPECIFICATIONS 3 3 ACCESSORIES 3 4 INSTALLATION INSTRUCTIONS 3 4 1 Choosing Proper Location for the Air Conditioner 4 4 2 Attach the Sealing gasket to the Roof Opening 4 4 3 Place the Unit in the Roof Opening 4 4 4 Secure the Unit to the Mounting Brackets 4 4 5 Connect Wiring 4 4 6 Install the Decor Panel 4 5 OPERATING INSTRUCTION...

Страница 3: ... risk involved Do NOT modify this product in any way Any modifications can be extremely hazardous Keep electrical devices out of reach of children and do not allow them to operate the device without supervision Only use accessories authorized by VELIT Do NOT use this unit in or near flammable environment Do NOT let children use the unit without supervision Do NOT use this unit when the ambient tem...

Страница 4: ...ll edges of the opening Route the 6AWG power cable to the roof opening Leave at least six inches of slack For cables longer than 10ft refer to NEC National Electric Code for proper sizing of wire 12V 60A 4 2 Attach the Sealing gasket to the Roof Opening Clean the surface between the unit and the roof where the sealing gasket will be installed Apply sealant to the bottom of the sealing gasket Place...

Страница 5: ...ease fan speed 4 Fan Speed Decrease fan speed 5 Temperature Increase setting temperature 6 Temperature Decrease setting temperature 5 2 Edit Low Voltage Protection Long press the Mode Switch to edit low voltage protection Press Fan Speed to increase cut off voltage Press Fan Speed to decrease cut off voltage Press Temperature to increase recover voltage Press Temperature to decrease recover voltag...

Страница 6: ...ambient temperature sensor E1 Faulty evaporator temperature sensor error E2 Over current protection E3 Blocked rotor protection E4 Low voltage protection E5 Short protection faulty controller E6 Over voltage protection E8 Faulty evaporator fan EF Condenser fan short over current faulty Eb Controller lack phase protection EU Controller overheated ...