1.

 

IMPORTANT SAFETY 

INSTRUCTION 

This manual has safety information to help users 
eliminate or mitigate the risk of accidents and 
injuries. 
 
The installation of this unit MUST comply with the 
following code:  
U.S

 NFPA1192, NFPA70 

CANADA: C22.1, CSA Z240 
 

1.1 Understand Signal Words 
 

  

Indicates a hazardous situation that if NOT 
avoided, could result in death or serious injury. 

  

Indicates a hazardous situation that if NOT 
avoided, could result in minor or moderate injury.

 

  

Indicates practices NOT related to physical injury 
 

 1.2 General Safety Message 

 

 

 

This unit MUST be installed and repaired by 

qualified personnel who are familiar with the risk 
involved.  

 

Do NOT modify this product in any way. Any 

modifications can be extremely hazardous. 

 

Keep electrical devices out of reach of children 

and do not allow them to operate the device 
without supervision. 

 

Only use accessories authorized by VELIT. 

 

Do NOT use this unit in or near flammable 

environment. 

 

Do NOT let children use the unit without 

supervision

 

 

 

 

Do NOT use this unit when the ambient 

temperature is lower than 40

°F. This could cause 

frost inside the unit. 

 

 

Do NOT power wash the unit or use detergent to 

clean the unit.

 

 

 

2.

 

SPECIFICATIONS 

 

 

Model 

R2000 

Input Voltage 

DC 12V 

Operating Current 

10-60A 

Cooling Capacity 

8000BTU/2300W 

Air Flow Rate 

450mc/h 

Rated Power 

650W 

Refrigerant 

R134a 750g 

Noise Level 

Eco mode: 60dB 

Boost mode: 75dB 

Roof Unit Dimension 

W31.7

x L31.7

H7.1

 

Inner Housing 

Dimension 

W13.8

x L11

x H4.3

 

Weight 

66lb 

 
 
 
 
 
 
 

Содержание R2000

Страница 1: ...1 Page ...

Страница 2: ...TION 3 1 1 Understand Signal Words 3 1 2 General Safety Message 3 2 SPECIFICATIONS 3 3 ACCESSORIES 3 4 INSTALLATION INSTRUCTIONS 3 4 1 Choosing Proper Location for the Air Conditioner 4 4 2 Attach the Sealing gasket to the Roof Opening 4 4 3 Place the Unit in the Roof Opening 4 4 4 Secure the Unit to the Mounting Brackets 4 4 5 Connect Wiring 4 4 6 Install the Decor Panel 4 5 OPERATING INSTRUCTION...

Страница 3: ... risk involved Do NOT modify this product in any way Any modifications can be extremely hazardous Keep electrical devices out of reach of children and do not allow them to operate the device without supervision Only use accessories authorized by VELIT Do NOT use this unit in or near flammable environment Do NOT let children use the unit without supervision Do NOT use this unit when the ambient tem...

Страница 4: ...ll edges of the opening Route the 6AWG power cable to the roof opening Leave at least six inches of slack For cables longer than 10ft refer to NEC National Electric Code for proper sizing of wire 12V 60A 4 2 Attach the Sealing gasket to the Roof Opening Clean the surface between the unit and the roof where the sealing gasket will be installed Apply sealant to the bottom of the sealing gasket Place...

Страница 5: ...ease fan speed 4 Fan Speed Decrease fan speed 5 Temperature Increase setting temperature 6 Temperature Decrease setting temperature 5 2 Edit Low Voltage Protection Long press the Mode Switch to edit low voltage protection Press Fan Speed to increase cut off voltage Press Fan Speed to decrease cut off voltage Press Temperature to increase recover voltage Press Temperature to decrease recover voltag...

Страница 6: ...ambient temperature sensor E1 Faulty evaporator temperature sensor error E2 Over current protection E3 Blocked rotor protection E4 Low voltage protection E5 Short protection faulty controller E6 Over voltage protection E8 Faulty evaporator fan EF Condenser fan short over current faulty Eb Controller lack phase protection EU Controller overheated ...

Отзывы: