4Kw Air Fuel Heaters
5
3.2.2
The sealing between the heater and the mounting surface must
be intact.
During installation, the sealing gasket provided by the
manufacturer must be used, and the mounting surface must be
flat.
Four M6 nuts provided by the manufacturer shall be used for
securing the unit at 6-7Nm. Note: When the heater is
reinstalled, the gasket must be replaced.