www.velgehome.com
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
FOR COOKER HOOD MODEL VBCH 5510.1W, 230-240 Vac - 50 Hz
Exhausting cooker hood. The equipment is constructed in accordance with European Standards and with the requirements included in the
following Directives: EN60335-1 ( Low Voltage Directive), EN55014-2 (Electromagnetic Compatibility).
INSTALLATION
Read the instruction manual before installing and/or using the hood.
The unit must be fitted at a distance of at least 60 cm. from the cooking
hob. If the mounting instructions of the gas cooker indicate a wider
distance, respect it. The unit must not be mounted above cookers fitted
with top radiant plate.
Respect all the air discharge regulations.
The air must not be discharged in a pipe used to discharge exhaust fumes
produced by gas-fed equipments or fuel-fed equipments (this does not
apply to filtering hoods).
The room must be adequately ventilated when the hoods is used together
with other gas- fed or fuel-fed equipments.
For an easy access, it is advisable to move possible furniture under the
installation area.
Installation of the hood onto the wall.
The hood is equipped with all the necessary fastenings for its installation,
which are suitable for most surfaces.
Verify that the installation surface is strong.
Installation must be carried out by qualified installers according to
present regulations.
•Drill into the wall unit as in
Figure 1
•Thread the hood and fasten it through the clamping hooks (A)
•Secure the screws (B) making sure that both brackets are in contact with
the shoulder of the wall unit
•Apply the two side caps, inserting them laterally and fixing the screws (C)
•Apply the aesthetic cover (D) to the hood by inserting it on the wall unit
and resting it on the hood.
ELECTRICAL CONNECTIONS
This equipment must be connected to a grounding plant. Two types of
electrical connection can be used:
1)Using a standard plug to be connected to the power cable and inserted
in a mains socket which must be accessible (so that the plug can be
disconnected when servicing is carried out). Make sure that the plug is
accessible also after the complete installation of the equipment.
2)By means of a fixed mains connection, fitting a bipolar switch, which
ensures the disconnection, with an opening distance of the contacts
allowing a complete disconnection on the conditions of the overvoltage
III category, according to installation regulations. The ground connection
(yellow-green wire) must not be interrupted.
Refer to the plate inside the hood for the mains voltage and frequency
ratings.
EMPLOYMENT
This cooker hood can be employed as
exhausting
or
filtering.
Exhausting
(external evacuation). Kitchen smokes are driven outside
through a flue joined to the exhaust pipe flue connector.