112
113
Owner’s Manual
The remaining battery capacity display interface
Fault code display
When the Electric bicycle electronic control system fails, the LCD Panel will
automatically display the fault code.
Note: Only the fault is solved, the instrument can exit from the fault code display. Turn
off the power supply before the fault is solved.
Fault
Code
Definition
04
Turn to no homing
05
Turn fault
06
Low voltage protection
07
Over voltage protection
08
Motor Hall signal line fault
09
Motor Phase line fault
10
Reach the high temperature protection point
11
Temperature sensor fault
12
Current sensor fault
21
Speed sensor fault
22
Battery communication fault
30
Instrument communication fault
<20%
20%-40%
40%-60%
60%-80%
80%-100%
Fault Code
Display Interface
Use Attention
Note that safe driving is necessary and avoiding collision of the instrument.