background image

12

Configuration and setting

Language selection

NOTE

Over the following pages, the field locating and selection method is primarily indica-
ted by the “vertical button movement” and “press button” icons. However, horizontal 
button movement can be used to locate and select fields, as indicated in the General 
equipment use.

NOTE

The equipment automatically accesses language selection a few sections after the 

welcome message is displayed. Language selection can also be accessed by going 
back from the main menu.

1) 

Locate and select the language: ESPAÑOL – 
ENGLISH – FRANÇAISE.

2) 

Access the main menu.

Manual setting

1) 

In the main menu, locate and select 
MANUAL.

NOTE

The cluster map on the equipment panel in-

dicates the cluster related to each submenu.

Filter allocation to antennas

NOTE

There are five different configurations to dis-

tribute the 10 filters among the 3 antennas.

1) 

Locate and select the aerial filter configuration 
(the aerial distribution is displayed at the top of the 
screen and the 10 filters available are displayed at 
the bottom):

 

J

For one antenna:

a)  Configuration (10 – 0 – 0)

 

J

For two antennas:

b)  Configuration (9 – 0 – 1)

Содержание IKUSI ONE Series

Страница 1: ...ONE series ONESAT ONE118 ONEHOME Programmable multichannel amplifiers Configuration and setting guide...

Страница 2: ...2 Configuration and setting...

Страница 3: ...uipment installation and configuration 10 Installation 10 Power connection 11 Quick menu guide 12 Language selection 12 Manual setting 15 Advanced settings 18 Self installation 19 Maintenance 19 Equip...

Страница 4: ...ng these instructions may lead to serious consequences to health and may even cause fatal injuries RIESGO DE DA O EN EL EQUIPO Este aviso de seguridad indica una posible situaci n peligrosa La no obse...

Страница 5: ...ts are covered or blocked Install the equipment in a location with at least 20 cm around it free of other objects J J Do not expose the equipment to rain or moisture Install the equipment in a dry loc...

Страница 6: ...ual adjustment of each frequency filter number of channels and automatic gain control allows for level equalize of selected channels J J Programming F F Self installation function F F All settings are...

Страница 7: ...10 UHF filters deli vering an output level of 118 dB V J J Inputs F F 5 terrestrial inputs BI FM BIII DAB UHF1 UHF2 UHF3 F F BI FM gain 35 dB F F BIII DAB gain 40 dB F F UHF gain 55 dB J J Outputs F F...

Страница 8: ...eet in page 22 Recommended for small installations made up of 10 UHF filters deli vering an output level of 118 dB V J J Inputs F F 2 terrestrial inputs BI FM UHF1 F F BI FM gain 2 dB F F UHF gain 40...

Страница 9: ...e equipment is switched on and after periods when the equipment is not in use Vertical button movement In the menus and submenus move the button up or down to browse upwards and downwards position by...

Страница 10: ...e ground cable 2 Connect the power plug to the equipment mains connector 3 Connect the power plug to the mains socket ATTENTION 12V 5A POWER CFP 700 VLNB QPSK IN SYNC STATUS 12V RF OUT IKUSUP CONTROL...

Страница 11: ...1 General gain BI BII input BIII DAB input UHF output VHF UHF EXT input SAT IF adjustment Self installation Input preamps Equipment information Lock Restore values cloning Manual setting Advanced set...

Страница 12: ...e accessed by going back from the main menu 1 Locate and select the language ESPA OL ENGLISH FRAN AISE 2 Access the main menu Manual setting 1 In the main menu locate and select MANUAL NOTE The cluste...

Страница 13: ...antenna 1 Locate and select the UHF input voltage VDC 24 12 2 Locate and select UHF input voltage enabling ON disabling OFF f UHF3 input voltage 3 ON OFF g UHF2 input voltage 2 ON OFF h UHF1 input vol...

Страница 14: ...at the level you have set 1 Locate and select the gain configuration mode AUT M i If AUT is selected self equalising is configured j If M is selected locate and select the gain level 00 30 General gai...

Страница 15: ...among high frequencies NOTE If TILT is selected the equipment applies 9 dB of pre emphasises 1 Locate and select TILT to change the level of pre emphasis between 0 and 9 dB Advanced settings 1 In the...

Страница 16: ...ent sending the information locate and select MASTER ON SLAVE OFF NOTE The time waited for cloning to be run steep 2 to 3 is 11 seconds Where cloning cannot be started the equipment returns to the hig...

Страница 17: ...alues Frequency plan NOTE You can choose between two different chan nel allocations for the UHF band These allo cations depend on the geographic territory By default the equipment is configured for th...

Страница 18: ...ins This is because the output level must be set by the installer to suit the network you are feeding 1 In the main menu locate and select AUTOINSTALL a If NO is selected you will return to the main m...

Страница 19: ...reign bodies Troubleshooting The most frequent problems arising during equipment installation are indicated below If you encounter any other type of problem please contact the equipment sales team Pro...

Страница 20: ...9 7 2 2 Gain dB 35 40 35 55 switchable Gain adjustment dB 25 20 30 Noise figure dB 6 Optimum input margin dB V 60 85 60 80 50 100 Return losses dB 10 Selectivity 10 MHz of channel ends dB 10 Uncoupli...

Страница 21: ...35 35 35 55 switchable 40 1 5 35 40 40 40 60 switchable 40 Gain adjustment dB 25 20 30 20 Noise figure dB 6 9 Optimum input margin dB V 60 85 60 80 50 100 40 80 Return losses dB 10 Selectivity 10MHz o...

Страница 22: ...r input 10 0 0 9 0 1 7 0 3 2 5 3 2 7 1 Gain dB 5 20 40 switchable Gain adjustment dB 30 Noise figure dB 6 Optimum input margin dB V 50 100 Return losses dB 10 10 Selectivity 10 MHz of channel ends dB...

Страница 23: ...ignals can be ignored when calculating the output reduction level If referred levels are not reduced as indicated those signals must be counted as normal channels and the output level de rated accordi...

Страница 24: ...tion or programme updates or the repair of any damages or injuries caused to the client or others as a result of the installation or of receiver operations Equipment recycling RECYCLING OF ELECTRICAL...

Страница 25: ...ug that joins the amplifier fig 3 5 Loosen the screws T4 T5 and T6 of the cover of the power supply and release it from the grooves R1 and R2 fig 4 5 6 Remove the power supply replacing it with the ne...

Страница 26: ...26 Configuration and setting ONE en P Miram n 170 20014 San Sebasti n SPAIN Tel 34 943 44 88 00 Fax 34 943 44 88 20 television ikusi com www ikusi tv...

Отзывы: