Softener
Mains water contains insoluble salts, which cause the build-up of lime scale deposits in the boiler
and in other parts of the machine. The softener makes it possible to eliminate or substantially reduce the
presence of these mineral salts. The resin softener has the property of retaining the calcium contained
in the water. For this reason after a certain period the resins are saturated and are to be regenerated
with coarse kitchen salt (NaCL, sodium chloride) or special water softening salt. It is very important
to regenerate the softener within the established times. The regeneration is to be done regularly every
15 days. However, in locations with very hard water, it will be necessary to regenerate more frequently.
The same is true of places in which there is a large consumption of hot water for tea or other use.
Softener regeneration
Proceed as follows:
0RYHOHYHUV
2
) and (
5
) from left to right;
5HPRYHWKHOLGE\ORRVHQLQJWKHNQRE
1
).
5HOHDVH HQRXJK ZDWHU WKURXJK WKH SLSH
3
) to make room for the amount of salt as required
depending on the model (see table).
&OHDQDQ\VDOWRUUHVLQUHVLGXHIURPWKHJDVNHWORFDWHGRQWKHOLG
3XWWKHOLGEDFNLQSODFHE\VFUHZLQJWKHNQRE
1
) down securely and move the lever (
2
) back from
right to left.
/HWWKHVDOWZDWHUGUDLQIURPWKHVPDOOWXEH
4
) until the water is no longer salty (about 30-60
minutes). The salt allows the accumulated mineral salts to be released.
%ULQJWKHOHYHU
5
) from right to left back to its initial position.
Model
softener
Amount
of salt
8 litres
1,0 kg
12 litres
1,5 kg
16 litres
2,0 kg
In order to keep the softener and hence the machine in perfect operating condition, it is necessary
to perform regeneration periodically based
on the use of the softener and the hardness
of the water that is used.
The table alongside shows the values of
the quantity of softened water based on the
hardness of the water in the various units
of measure:
- °f: French degree
- °d: German degree = 1,8 °f
- mg CaCO3
For further information on installation, start-up and regeneration of the softener, refer to the
relative instruction manual.
Amount of softened water based on hardness
°f
30°
40°
60°
80°
salt
°d
16,5°
22°
33°
44°
mg CaCO3
30
40
60
80
8 litres
1000 lt 900 lt
700 lt
500 lt 1,0 kg
12 litres
1500 lt 1350 lt 1050 lt 750 lt 1,5 kg
16 litres
2100 lt 1800 lt 1400 lt 1000 lt 2,0 kg
The build-up of lime scale in the hydraulic circuit and boiler inhibit thermal exchange,
thus compromising proper operation of the machine. Heavy incrustation in the boiler
may cause long machine shutdowns and in any case invalidate any guarantee, because
this symptom indicates that regeneration has been neglected.
i
2
5
1
3
4
Содержание DISPLAY ELEGANCE
Страница 1: ...instruction manual for user ENGLISH VELA EPU EVD DISPLAY ELEGANCE EMA...
Страница 6: ...146 english...
Страница 12: ......
Страница 18: ......