1.5. SAFETY

This chair bears the CE mark and 
approved under the model name 
”VELA Tango” and conforms to all 
applicable EU rules. The chair is 
manufactured by VELA Medical, 
Goeteborgvej 8-12, 9200 Aalborg 
SV, Denmark.

The VELA Tango 310E with electrical 
functions meets all safety require-
ments according to IEC 60601-1, 
including requirements for EMC 
according to IEC60601-1-2. 

 
1.5.1. INTENDED USE

This device is intended to support 
a bariatric user in a sitting posture 
while performing indoor activities of 
daily living, including work activities.

::

  The chair is not built to stand on

:: 

The wheel brake must always be 
activated when sitting down or 
standing up

All variants of VELA Tango 310 are 
tested and approved for a maximum 
load of 200 kg. For optimal use, the 
chair‘s recommended user weight is 
130-160 kg.

All variants of VELA Tango 310E are 
tested and approved for a maximum 
load of 300 kg. For optimal use, the 
chair‘s recommended user weight is 
130-300 kg.

1.5.2. TRANSPORT

When transporting the chair by 
car, airplane or any other means of 
transport, always use the chair brake. 
The chair is not approved for use as 
a passenger seat in any means of 
transportation and may not be used 
as such.

The chair is designed to be 
transported under the following 
environmental conditions:  

Temperature: - 20°C to + 60°C
Humidity: 15-95%

Allow the chair to stand for 24 hours 
before use if it has been stored 
below - 10°C.

IN GENERAL

Содержание Bariatric

Страница 1: ...cal ISO 9001 ISO 14001 I N S T R U C T I O N F O R U S E E N Manual no 106065 The chair s design varies depending on the model Item no Model 5027 VELA Bariatric Patient Chair 5107 VELA Bariatric Patie...

Страница 2: ...8 1 8 2 Frame 8 1 8 3 Padding 8 1 8 4 Recycling guide 9 1 9 RECYCLING AND DISPOSAL 9 2 0 USER MANUAL 10 2 0 1 Height adjustment El 10 2 0 2 Height adjustment Manual 10 2 0 3 Handheld control El 10 2 0...

Страница 3: ...r later use This user manual must always accompany the chair The user manual is also available on VELA Medical s website www vela medical com where you also can find other relevant information about t...

Страница 4: ...height adjustment for more than two minutes at a time Use In the event of an electrical error or unintentional height adjustment push both of the buttons for height adjustment simultaneously for 10 se...

Страница 5: ...the height without sitting in the chair If this does not work the gas cartridge is defective and should be replaced Contact your VELA Medical supplier The brake function does not work The brake is not...

Страница 6: ...e read at a distance of approx 40 cm under normal daylight conditions For labels related to the operation of the chair please refer to section 2 0 Follow instructions for use IP21 EN60601 1 Blade fuse...

Страница 7: ...ys be activated when sitting down or standing up All variants of VELA Tango 310 are tested and approved for a maximum load of 200 kg For optimal use the chair s recommended user weight is 130 160 kg A...

Страница 8: ...Medical supplier right away In such cases do not attempt to use the chair or to fix it yourself On delivery you have received VELA Medical Chair Instructions for use Charger only for chairs with elec...

Страница 9: ...will help prevent negative effects on the environment and people Note Electrical and electronic equipment and accompanying batteries contain materials com ponents and substances that can be harmful t...

Страница 10: ...t or left armrest Note VELA Tango El is also available with height adjustment via handheld control see item 2 0 3 2 0 4 ADJUSTMENT OF SEAT DEPTH The seat depth is adjusted by loosening the 2 Unbrako b...

Страница 11: ...adjusting the height of the armrest Remember to tighten the screws securely again 2 0 8 ADJUSTING THE ARMREST WIDTH Adjust by loosening both screws under the seat Remember to tighten the screws secur...

Страница 12: ...chair is charging and green when the chair is fully charged Note The chair should not be used during charging 2 0 9 BRAKE The brake on the chair is activated by moving the handle on the side of the ch...

Страница 13: ...rovides a stable seat on uneven skewed surfaces Note On the electric version it is advisable to activate or deactivate the brake completely when using this feature Depending on model 2 0 14 ACCESSORIE...

Страница 14: ...1 4...

Страница 15: ...1 5...

Страница 16: ...701 640 7 Vermund Larsen A S VELA Medical G teborgvej 8 12 9200 Aalborg SV Denmark 45 96 34 76 00 mail vela medical com vela medical com...

Отзывы: