Veko Joris Скачать руководство пользователя страница 13

Pool

IP65

Applicable

 

products

     Profiles

Mounting

Coupling

Suspension

Pool application

Not all standard components can be used in a pool environment. Due to high humidity as well as vapors of chlorine 

andcleaning products, high levels of corrosion can occur. To prevent corrosion, all aluminium profiles, including 

mounting brackets and coupling pieces (as shown on this page) will be finished with a anodized layer of at least 

25μm (according to standard). To protect the LED's, the LED-board will be provided with an extra protective coating. 

All used suspension material (as shown on this page) will be hot dip galvanized. 

Important notes

After installation, inspection off all used products is necessary due to safety regulations.

This inspection should be on a regular basis and occur at least once a year.

This inspection is the sole responsibility of the end user.

Applicable standards

All Veko swimming pool products and components meet the following standards:

NEN 1010 Safety for low voltage installations;

NEN-EN 12193 Lights and lighting - sports lighting;

NEN-EN 15288-1 Safety requirements for design;

NEN-EN 60598-1 Lighting fixtures - Part 1: General requirements and tests;

NEN-EN 60598-2-22 Lighting fixtures - Part 2-22: Particular requirements for emergency lighting fixtures;

NPR 9200 Metal suspension structures and fasteners in swimming pools.

13/16

Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Pool

Содержание Joris

Страница 1: ...oduct families on this page in IP65 specification only In combination with the following linear lighting profiles PWR 05500 PWR 05500 B For further information of applicable profiles see section 3 of...

Страница 2: ...nnectors Single unit re placement Sensor MD L re placement Sensor configuration s Pool Emergency LED indicator battery replacement Emergency system info disclaimers General disclaimers Page 3 4 5 6 7...

Страница 3: ...easurement E deviding E equally over 2 lineparts 4 In case of Cable duct Sports utility Swimming pool Always use a suspension with at least 3 points IP65 Measurement Recommended length mm Maximum leng...

Страница 4: ...wire left KDW hook chain and S hook right 9 Always close the links of both the KDW and S hook 10 Close the link of the S hook 11 Close the link of the KDW hook 12 Example of mounting with threaded en...

Страница 5: ...gether 9 Tighten Hexagon M5 screws 2x on both sides of the profiles 10 Hook the coupling plate into the profiles 11 Rotate the plate into position 12 Tighten the slotted M6 bolts 4x IP65 6 9 3 12 4 Ma...

Страница 6: ...s Profile Mounting Coupling Note Applicability of bracket may vary depending on the surrounding light line configuration light line application and or IP class IP65 6 16 Manual Veko linear lighting sy...

Страница 7: ...erpart on the linear lighting system 8 Insert the connector 9 Connectors should firmly click into eachother 10 Tighten the M5 hexagon bolts on both sides of the light line 11 Hook the coupling plate i...

Страница 8: ...ng all electrical con nections are correctly in place and corresponding switch the mains back on IP65 5 8 9 10 5 Place the feed onto the light line aligning the connection plates Tighten the M5 Hexago...

Страница 9: ...onto the unit and profile 5 on either side of the unit equally devided 10 Caution Bracket may contain sharp edges 11 Caution Make sure wiring doesn t get stuck between the unit and the profile and is...

Страница 10: ...the desired reach and angle of the sensor beam 8 Technical data 9 Sensor reach MD L R round lens MD L Na narrow lens IP65 Technical data Power W 1 5 W 4 W Switched off on Voltage V 220 240 V Length m...

Страница 11: ...on or off for a set amount of hours Hold until light responds Hold until light responds 1x Fast Blink Fast Blink Fast Blink Fast Blink Fast Blink Fast Blink Fast Blink Fast Blink Slow Blink 3x Flash...

Страница 12: ...Check the programmed setting of 3 1 Detection accuracy 3 2 Sensitivity twilight mode 4 Red LED Setting The red LED flashes when detected This can be turn ed off or on It s recommended to turn the red...

Страница 13: ...galvanized Important notes After installation inspection off all used products is necessary due to safety regulations This inspection should be on a regular basis and occur at least once a year This i...

Страница 14: ...EN 1838 NEN EN IEC 60598 2 22 8 LED color flashing Error condition Cause Solution Green no flashing System OK battery fully charged Off Main off EM mode Rest mode test in progress Green slow 0 25s on...

Страница 15: ...inaire are both DALI gear then each can be separately addressed on the same DALI bus This allows common wiring to be used for both normal lighting control and emergency test control During a failure o...

Страница 16: ...luminaire a closed system and not an electrical installation at itself The light source of this product is custom made and shall only be replaced by the manufacturer or his service agent At end of lif...

Отзывы: