Sensor MD-L (re-)placement
1
2
3
4
5
6
7
8
MD-L-Na
MD-L-R
1 Disconnect the mains before operating the
linear lighting system.
2 Example of sensor.
Note
: type of sensor and/or
profile may vary.
3 Make sure poles and wiring are in correct
position.
4 Insert connector to flatcable.
5 Press and mount the fallout safety clip
into the profile.
6 Fit the sensor unit into the profile
7 In case of the narrow lens, a cover
can be used to limit the reach of the
sensor beam if necessary.
- Length -
- Width -
9
-This cover can be cut to size with pliers
or scissors on the breakline to achieve the desired
reach and angle of the sensor beam.
8 Technical data.
9 Sensor reach:
MD-L-R (round lens)
MD-L-Na (narrow lens)
IP65
Technical data
Power (W)
1,5 W < 4 W (Switched off- < on)
Voltage (V)
220-240 V
Length (mm)
300 mm
Frequency (Hz)
50 ÷ 60 Hz
Circuit
6 A
Sensitivity settings
5 (standard max. sensitivity)
Twilight circuit
Adjustable in 9 steps 0-1.000 Lux
Switch-off delay relay
Relay 0-99 minutes
Environment application
-25 °C - + 35 °C
Corridor function / dynamic switch (example:
10-100 %)
In combination with DALI driver and control
gear
Programming
Readout and re-programmable by colour coding
with LED in sensor
PIR detection angle
Round 130 - 140
ENEC certification
In application at DEKRA
Warrenty
5 years
10/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Sensor (re-) placement