Alarm In/Out (ALARM/AUX)
Used for connecting alarm sensor, alarm annunciation device to Veilux VPIP-D1XXX-O / VPIP-D1XXX-I.
Class
Description
Alarm IN
Sensor In (+). NC/NO Selectable in Admin Mode
Alarm IN GND
Ground for Sensor In
Aux OUT
Alarm Output Terminal
Aux OUT(GND)
Ground for Sensor Output
Aux
Relay output is provided for connecting alarm devices or for remote on/off control of devices such as light.
Relay is normal open and it will be closed upon alarm annunciation or remote on. The relay is capable
of switching
30V AC/DC, 2A
. For the application which needs power switching beyond this limit, use
additional relay switch as shown as below figure.
Fig 2-5. Relay Connection Diagram(Left : lower than 30V, 2A, Right : Higher than 30V 2A)
Alarm
Connect external alarm sensor. Examples of sensing devices are infrared sensor, motion sensor,
heat/smoke sensor, magnetic sensor, etc.
Connect the two wires of the sensors to “SNS In”. The sensor
type (NC/NO) can be set in admin page. 10mA can be flown into sensor device. Multiple sensor devices
can be connected in parallel.