SVEX-Q18 Explosion proof Camera Manual
Book
Ver: 0.1
17
4.2.2
Camera Address Set
Decimal system is used for camera address, K1
、
K2
、
K3 dip switches are for address setting. K1 stands for
the unit digit, K2 is for tens digit and K3 for hundreds digit. Other K4 is for baud rate and K5 for control protocol.
e.g if the camera address is No.2, the K1 needs be 1 and K2, K3 should be 0, see below table:
Dip Switch
K3
K2
K1
Address
0
0
2
If the camera address is No.138, the K1 needs be 8, K2 is 3 and K3 should be 1, see below table:
Dip Switch
K3
K2
K1
Address
1
3
8
4.2.3
Communication Protocol Set
Check the protocols in the control system and then set K5 as below table. The new setting will work after
power on again.
Table 2: Protocol setting (K5)
Dip Switch
Protocol
1
PELCO-P
2
PELCO-D
4.2.4
Baud Rate Setting
Set baud rate with K4 as below table. The new setting will work after power on again.
Table 3: Protocol setting (K4)
Dip Switch
Baud Rate
0
Remote Control
1
1200
2
2400
3
4800
4
9600
5
19200