-24-
distance
Slave qty
Up to 127
Frame length
44 bytes ~ 1498 bytes
Process data
Single Ethernet frame with up to 1486 bytes
◼
Wiring
PLC can realize EtherCAT bus communication through CN3 port, and the requirements for
communication network cable are as follows:
Communication network cable requirements
Network port
connector registered
jack-8P9C-3 fork
Network port
connector registered
jack-8P9C-3 fork
26AWG Cat5e shielded twisted pair
Shielded cables
Common cables
Signal lead distribution
Pin
Signal
Direction
Description
1
TD +
Output
Data transm
2
TD -
Output
Data transmission -
3
RD +
Input
Data rec
4
-
-
NULL
5
-
-
NULL
6
RD -
Input
Data reception -
7
-
-
NULL
8
-
-
NULL
Length requirement
When using EtherCAT bus, the cable length between devices should not exceed 100 meters,
which will attenuate the signal and the normal communication.
Technical requirements
100% conduction test, no short circuit, open circuit, dislocation and poor contact. It is
recommended to use the following specifications of the cables.
Item
Specification
Cable Type
Resilient Crossover Cable, S-FTP, Cat5e
Standard
EIA/TIA568A, EN 50173, ISO/IEC 11801
EIA/TI Abulletin TSB
EIA/TIA SB40-A & TSB36
Section
AWG26
Type
Twisted pair
Line pair
4