SI30 Solar Pump Inverter Manual
21
★
Running Control Parameters
Funct
ion
code
Function name
Setting range and definition
Default
setting
prop
erty
Comm.
Add
F1.07
Stop mode
0
:
Deceleration to stop
1
:
Free stop
0
●
0x107
F1.13
Acceleration/decelerat
ion mode
LED "0"digit, acceleration
/deceleration time reference
0
:
Maximum frequency
1
:
Fixed frequency
LED"00"digit
:
Acceleration/deceleration mode
0
:
Linear
1
:
S curve
LED"000"digit
:
Reserve
LED"0000"digit
:
Reserve
0001
〇
0x10D
F1.31
Terminal running
protection function
LED "0"digit
:
Terminal running
command selection when power on
0
:
invalid when power on
1
:
valid when power on
LED”00” digit: Terminal running
command selection while running
command given channel switchover
0
:
Terminal running command is
invalid when switching
1
:
Terminal running command is
valid while switching
0011
●
0x11F
★
Switch Terminal Parameters
Functi
on
code
Function name
Setting range and definition
Default
setting
prop
erty
Comm.
Add
F2.00
Multi-function terminal
1 (X1)
0
:
No function 1
:
Forward
2
:
Reverse 6
:
Free stop
7
:
Emergency stop
8
:
Fault reset
9
:
External fault input
10
:
Water full detection fault
11
:
Water full detection fault Reset
22
:
PID control cancel
23
:
PID control pause
1
●
0x200
F2.01
Multi-function terminal
2 (X2)
See X1
2
●
0x201
F2.02
Multi-function terminal
3 (X3)
See X1
10
●
0x202
F2.03
Multi-function terminal
4 (X4)
See X1
11
●
0x203