SI30 Solar Pump Inverter Manual
12
Stop/reset key
Machine stops if press it while run/stop is controlled by keyboard.
Its efficiency range is defined via function no [F4.03]. Inverter
resets if press it in fault state (no reset if fault is not solved).
Keyboard
potentiometer
Can be used as input channel for given frequency, upper
frequency limit, given torque, given PID or PID feedback setting.
●
Indicator Light Meanings
Name
State
Meaning
Unit
indicator
light
Hz
Spark
Digital display given frequency.
Hz
On
Digital display output frequency.
A
On
Digital display actual output current.
V
On
Digital display input voltage.
V
Spark
Digital display output voltage.
S
On
Time unit is second.
S
Spark
Time unit is ms, min, or h.
RPM
On
Digital display motor speed.
%
Spark
Digital display given PID.
%
On
Digital display PID feedback.
State
indicator
light
FWD
On
Inverter is forward rotating.
FWD
Spark
Inverter is reverse rotating.
FWD
Off
Inverter stops.
Function
indicator
light
REV/JOG
On
Jog.
REV/JOG
Off
Reverse.
●
Parameter Initialization
Setting F0.19 = 1 to complete the initialization of parameters. Specific operations as follows: