16
When the servomotor is enabled but not running and is in a stop state, when the brake (/BK) signal and the servo ON
(/S-ON) signal are OFF at the same time, setting this parameter can change the time of the brake signal (/BK) off to the
time when the motor is actually not in power.
Pn009
Brake delay of electromagnetic brake
10~100
50
10ms
0x0009
Immediate
effect
When the servo motor rotates in the servo OFF/, when the alarm / main circuit off occurs, the servomotor is not energized,
and the output time of the brake signal (/BK) OFF can be adjusted by this parameter and the braking delay time of the
brake (any one meet).
Pn010
Delay release speed of brake for
electromagnetic brake
0~10000
100
rpm
0x0010
Immediate
effect
Pn012
External regeneration resistance power
0~65535
0
10W
0x0012
Immediate
effect
Pn013
External regenerative resistance
0~65535
0
mΩ
0x0013
Immediate
effect
Pn015
Overload warning value
1~100
20
%
0x0015
Power
failure
effective
Setting this parameter can change the overload warning detection time, for example, the overload warning time at the
factory is 20% of the overload alarm detection time.
Pn016 Motor current overload detection base
current derating setting
10~100
100
%
0x0016 Power
failure
effective
Pn030 Retention parameter
0~65535
0
-
0x0030
Immediate
effect
Pn031
Parameter modification operation
locking
0~1
0
-
0x0031
Power
failure
effective
0- allows the panel to modify the parameter 1-. No panel modification parameters are allowed.
Function
code
Parameter name
Range
Default value
Company
Postal
address
Effective
way
Pn040
The use of absolute encoder
0~1
0
-
0x0040
Power
failure
effective
0- uses absolute encoder as absolute value encoder 1- uses absolute encoder as incremental value encoder:
Pn041
Alarm / warning selection for absolute
encoder battery under voltage
0~1
0
-
0x0041
Power
failure
effective
0- sets the battery voltage low to 1- and sets the battery voltage low as a warning.
Pn044
Full closed loop application related
switch
0-51
1
-
0x0044
Power
failure
effective
The 0: encoder has pulse frequency output, the grating ruler power is effective, the grating ruler signal does not filter the
1: pulse output, the grating ruler power is effective, and the grating ruler signal is not filtered.
18: encoder pulse frequency output, grating scale power supply invalid, 0~4MHZ filter
Содержание SD700-1R1A series
Страница 10: ...10 1 10 Example of location control connection...
Страница 11: ...11 1 11 Example of speed control connection...