Specifications
Image sensor
2 Mega Pixels
Photo resolution
1920 x 1080, 1280 x 720, 640 x 480
Video resolution
1920 x 1080, 1280 x 720, 640 x 480
Focus range
Manual focus from 0mm to 150mm
Magnification ratio
10x or 200x
Video format
AVI
Photo format
JPEG
Light source
8 LEDs (brightness adjustable)
PC interface
USB2.0
Power source
5V DC from USB port
System requirements
Windows 7/8/10, Mac 10.12 and later
Languages
English, German, Spanish, Russian, Italian, French, Portuguese, Dutch, Polish,
Japanese, Korean, Chinese
Bundle software
MicroCapture Plus (with measurement for Win/Mac)
Dimensions
Microscope: 110mm x 33mm
Troubleshooting
Problem
Solution
Photo capture or video is blurred or shaky
The image is not in focus, correct this by turning the Focus Wheel.
Use the microscope stand when capturing images to avoid shake.
Microscope does not turn on
Try a different USB port .
Download the Micro Capture Plus software.
Screen is blank
Ensure that the software is open and the scope is plugged in.
Check the item you want to view is positioned correctly under the
lens. Ensure the scope is focused.
Image looks smudged or blurred
Clean the screen and lens carefully with supplied cloth.