Aqua-Hot™  Hydronic Heating System Owner’s Manual  07/04

Page  4

2.2  Activating the Electric Heating Element for the AHE-100-04S Model

SECTION 2:  ACTIVATING THE AQUA-HOT’S HEAT SOURCES

Electric

Element

Operation

AHE-100-04S

Electric Heating Element

Turn the 

Electric

 switch 

ON

; reference 

Figure 3

.  This procedure will

activate the 120 VAC Electric Heating Element and the indicator light

located on the Electric switch.  Allow 1-2 hours for the Aqua-Hot System to

reach operating temperature.  Please note that the Electric Heating

Element is a 

secondary heat source

 for heating both the interior and the

domestic hot water during low heating demand situations (such as when

moderate ambient temperatures exist and/or when there is a low demand

for domestic hot water).

NOTE:

Both the Diesel-Burner and the Electric Heating Element are

thermostatically controlled.  Either, or both, heating sources will

automatically maintain the temperature of the Aqua-Hot's water and

antifreeze solution between approximately 160-190 (+/- 5) degrees

Fahrenheit.   To heat your motorhome / domestic hot water, simply

choose the desired heat source(s) and leave the switch(s) (i.e., Diesel

and/or Electric)

ON

.

2.3  Activating the Electric Heating Element(s) for the AHE-130-04X Model

SECTION 2:  ACTIVATING THE AQUA-HOT’S HEAT SOURCES

Electric

Element

Operation

AHE-130-04X

Electric Heating Element(s)

Low:

Turn the 

Electric

 switch 

ON

in conjunction with the High / Low switch

placed in the 

LOW

 position; reference 

Figure 3

.  This procedure will

activate one of the two 120 VAC Electric Heating Elements and the

indicator lights located on both the Electric and High / Low switches.  Allow

1-2 hours for the Aqua-Hot System to reach operating temperature.

High:

Turn the 

Electric

 switch 

ON

in conjunction with the High / Low switch

placed in the 

HIGH

 position; reference 

Figure 3

.  This procedure will

activate both of the 120 VAC Electric Heating Elements and the indicator

lights located on both the Electric and High / Low switches.  Allow 0.5-1

hour for the Aqua-Hot System to reach operating temperature.

NOTE:  

In order to operate both Electric Heating Elements, you will either

need a 50-AMP Shore Power electrical source, or your Generator must be

capable of producing the necessary VAC electrical power requirements. 

Please contact the manufacturer of your specific motorhome for information

regarding the specifics of your motorhome’s electrical system.

SECTION 2:  ACTIVATING THE AQUA-HOT’S HEAT SOURCES

Содержание Aqua-Hot AHE-100-04S

Страница 1: ...Aqua Hot Hydronic Heating System Owner s Manual 07 04 Aqua Hot Motor Coach Heating System Owner s Manual 08 03 OWNER S MANUAL Model Number AHE 100 04S 12 VDC AHE 130 04X 12 VDC...

Страница 2: ...l To OWNER S INFORMATION Owner s Name Address City State Zip Code Telephone E mail Address Motorhome Model Date of Purchase Motorhome Aqua Hot Model No reference Figure 1 Marking Plate Aqua Hot Serial...

Страница 3: ...ot Water System 6 3 3 Using the Engine Preheat System 6 3 4 Diesel Burner Component Overview 7 3 5 Diesel Burner Operational Flow Chart 7 3 6 Precautions 8 Section 4 Maintenance 4 1 Maintenance Schedu...

Страница 4: ...heating with hot water that provides a continuous on demand supply of domestic hot water as well as interior zone heating where and when it is needed Both heating features are accomplished by a uniqu...

Страница 5: ...Serial Number Electric Heating Element AC Power Manufactured Date Fuel Type Firing Rate 02 637 120 VAC 60 Hz 1 65 kW 06 02 DIESEL 50 000 BTU R Testing Engineers International Listing No 02L02 Complie...

Страница 6: ...ments Reference page 8 for operating instructions SECTION 2 ACTIVATING THE AQUA HOT S HEAT SOURCES Diesel Burner Operation 2 1 Activating the Diesel Burner Diesel Burner Turn the Diesel switch ON refe...

Страница 7: ...the switch s i e Diesel and or Electric ON 2 3 Activating the Electric Heating Element s for the AHE 130 04X Model SECTION 2 ACTIVATING THE AQUA HOT S HEAT SOURCES Electric Element Operation AHE 130...

Страница 8: ...Aqua Hot is at operating temperature the domestic water is automatically heated as it is being used Because the Aqua Hot does not store any hot water simply open any hot water faucet and a continuous...

Страница 9: ...Turn OFF the Aqua Hot s Engine Preheat switch whenever engine preheating is not desired NOTE The Aqua Hot s Engine Preheating System acts as a supple mental heating source in addition to the Diesel Bu...

Страница 10: ...tat which senses coolant temperature reaches the preset temperature of approximately 190 5 degrees Fahrenheit NOTE If process A occurs the Heating Status and Diesel Burner Status lights on the Electro...

Страница 11: ...it is at the proper level Do this by visually checking the coolant level in the Aqua Hot s Expansion Tank reference Figure 1 Please note that the coolant level should be checked only when the Aqua Hot...

Страница 12: ...the Aqua Hot s Boiler Tank Failure to do so will cause serious damage to the Heater Upkeep continued Fuel Nozzle 0 35 GPH Combustion Chamber Fuel Filter 10 Micron Figure 5 SECTION 5 WINTERIZATION 5 1...

Страница 13: ...RVIA Standard write to Recreation Vehicle Industry Association 1896 Preston White Drive P O Box 2999 Reston VA 20195 0999 or visit the RVIA website at www rvia com Storage continued SECTION 6 TROUBLE...

Страница 14: ...ator Light This indicator light will illuminate RED whenever the VDC voltage level is too low for the Aqua Hot to operate properly This fault must be manually reset after the voltage level has been re...

Страница 15: ...ease note that this light will only be active if the Engine Preheat switch is ON in conjunction with either the Diesel and or the Electric switch If this indicator light illuminates RED it indicates a...

Страница 16: ...the Heater by the end user This warranty does not apply to damage or failure of the AQUA HOT Heater or the vehicle into which it was installed due to improper installation assembly maintenance abuse...

Страница 17: ...Aqua Hot Hydronic Heating System Owner s Manual 07 04 Date Service Performed Service Center OWNER S SERVICE LOG Date Service Performed Service Center OWNER S SERVICE LOG Continued...

Страница 18: ...Aqua Hot Hydronic Heating System Owner s Manual 07 04 MEMO MEMO...

Страница 19: ...s Manual 07 04 Aqua Hot Motor Coach Heating System Owner s Manual 08 03 15549 East Highway 52 Fort Lupton Colorado 80621 1 800 685 4298 Fax 303 857 9000 Copyright 2003 Vehicle Systems Inc All rights r...

Отзывы: