Version 0.4
26 February 2004
Page 24 of 33
For use with Vega 50 10 FXO – H.323 version 09.01.05.2 T004 or greater.
© 2004 VegaStream Ltd.
Set Longest ring-off time = length of longest silence in the incoming ringing voltage cadence
Set Shortest ring-on time = length of shortest ring in the incoming ringing voltage cadence
select
Table 1 lists the standard values to use in the UK and USA.
Table 1. Ring tones parameters
Country
UK
USA
Longest silence
2000ms
4000ms
Ring tone values
Shortest ring
400ms
2000ms