9 Supplement
VEGAVIB 63 • - contactless electronic switch
29278-EN-160122
Modes (switchable)
min./max.
Switching delay
Ʋ
When immersed
0.5 s
Ʋ
When laid bare
1 s
Ambient conditions
Ambient temperature on the housing
-40 … +80 °C (-40 … +176 °F)
Storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
Measured variable
Limit level of solids
Process pressure
-1 … 16 bar/-100 … 1600 kPa (-14.5 … 232 psig)
6 bar
(87psi)
-50°C
(-58°F)
16 bar
(232psi)
50°C
(122°F)
100°C
(212°F)
0°C
(32°F)
150°C
(302°F)
200°C
(392°F)
250°C
(482°F)
1
2
Fig. 28: Process pressure - Process temperature
1 Process temperature
2 Process pressure
VEGAVIB 63 of 316L
-50 … +150 °C (-58 … +302 °F)
Process temperature (thread or flange
temperature) with temperature adapter
(option)
-50 … +250 °C (-58 … +482 °F)
1
2
3
-50°C
(-58°F)
50°C
(122°F)
40°C
(104°F)
-40°C
(-40°F)
80°C
(176°F)
0°C
(32°F)
100°C
(212°F)
150°C
(302°F)
200°C
(392°F)
250°C
(482°F)
Fig. 29: Ambient temperature - Process temperature
1 Process temperature
2 Ambient temperature
3 Temperature range with temperature adapter