background image

6

3 Mounting

VEGASON 62 • Foundation Fieldbus

51862-EN-210616

3 Mounting

3.1  Mounting instructions

The reference plane for the measuring range is the lower edge of the 

transducer.
Make sure that a minimum distance from the reference plane - the 

so-called dead zone, in which measurement is not possible - is 

maintained. The exact value of the dead zone is stated in chapter " 

Technical data

". 

1

2

Fig. 1: Minimum distance to the max. level
1  blocking distance

2  Reference plane

Mount the sensor at least 200 mm (7.874 in) away from the vessel 

wall.

1

2

> 200 mm

Fig. 2: Mounting on round vessel tops
1  Reference plane

2  Vessel center or symmetry axis

Reference plane for 

measuring range

Mounting

Содержание VEGASON 62

Страница 1: ...Quick setup guide Ultrasonic sensor for continuous level measurement VEGASON 62 Foundation Fieldbus Document ID 51862...

Страница 2: ...ay and adjustment module PLICSCOM 9 5 1 Insert display and adjustment module 9 5 2 Setup steps 9 5 3 Menu schematic 12 6 Set up with smartphone tablet PC notebook via Bluetooth 14 6 1 Preparations 14...

Страница 3: ...lying with all prevailing regulations and directives The instrument must only be operated in a technically flawless and reliable condition The operator is responsi ble for the trouble free operation o...

Страница 4: ...lt information from measuring transduc ers NE 53 Compatibility of field devices and display adjustment components For further information see www namur de 1 7 Environmental instructions Protection of...

Страница 5: ...rovals process seal process temperature signal output voltage supply protection protection class Data matrix code for VEGA Tools app SIL identification with SIL rating ex works Move to www vega com an...

Страница 6: ...the so called dead zone in which measurement is not possible is maintained The exact value of the dead zone is stated in chapter Technical data 1 2 Fig 1 Minimum distance to the max level 1 blocking d...

Страница 7: ...sor through the cable entry 6 Lift the opening levers of the terminals with a screwdriver see following illustration 7 Insert the wire ends into the open terminals according to the wir ing plan Fig 3...

Страница 8: ...2 Wiring plan single chamber housing I2C Display 1 1 2 5 6 7 8 Fig 4 Wiring plan single chamber housing 1 Voltage supply signal output 4 3 Wiring plan double chamber housing I2C 1 1 2 Fig 5 Wiring pla...

Страница 9: ...ositions in 90 offset can be selected and turn to the right until it clicks into place 3 Screw housing lid with inspection window tightly back on Disassembly is carried out in reverse order The displa...

Страница 10: ...ica tion for example Aqueous solution Medium Liquid 4 Select in the menu item Application the vessel the application and the vessel form for example Storage tank Vessel shape Storage tank The sensor m...

Страница 11: ...nd weld joints on the vessel walls cause interfering reflections which can impair the measurement A false echo storage detects and marks these false echoes so that they are no longer taken into accoun...

Страница 12: ...is area 5 3 Menu schematic Information Depending on the version and application the highlighted menu windows may not always be available Basic adjustment Basic adjustment 1 Display Diagnostics Service...

Страница 13: ...c adjustment 4 Display Diagnostics Service Info False signal suppression 4 1 Change now Extended setting 4 2 Fast level change 1 m min Simulation 4 3 Start simulation Reset 4 4 Reset now Unit of measu...

Страница 14: ...ooth 1 Switch On Bluetooth active Off Bluetooth not active The security concept of Bluetooth operation absolutely requires that the default setting of the sensor PIN be changed This prevents unau thor...

Страница 15: ...IN is still effective Note Bluetooth access can only be established if the current sensor PIN differs from the default setting 0000 It is possible both when the PIN is deactivated and when it is activ...

Страница 16: ...sage Con necting is displayed For the first connection the operating device and the sensor must authenticate each other After successful authentication the next con nection functions without authentic...

Страница 17: ...able Measured variable distance between lower edge of the transducer and medium surface Measuring range Liquids up to 8 m 26 25 ft Bulk solids up to 3 5 m 11 48 ft Dead zone 0 4 m 1 312 ft Electromech...

Страница 18: ...18 Notes VEGASON 62 Foundation Fieldbus 51862 EN 210616...

Страница 19: ...19 Notes VEGASON 62 Foundation Fieldbus 51862 EN 210616...

Страница 20: ...ing scope of delivery application practical use and operat ing conditions of the sensors and processing systems correspond to the information available at the time of printing Subject to change withou...

Отзывы: