background image

T

he following assumptions form the basis for the implemen

-

tation of

FMEDA

:

l

F

ailure rates are constant

,

wear of the mechanical parts is

not taken into account

l

F

ailure rates of external power supplies are not taken into

account

l

M

ultiple errors are not taken into account

l

T

he average ambient temperature during the operating

time is

40

°

C

(

104

°

F

)

l

T

he environmental conditions correspond to an average

industrial environment

l

T

he lifetime of the components is around

8

to

12

years

(

IEC

61508

-

2

,

7

.

4

.

7

.

4

,

remark

3

)

l

T

he repair time

(

exchange of the measuring system

)

after

an nondangerous malfunction is eight hours

(

MTTR

=

8

h

)

l

T

he processing unit can interprete

"

fail low

"

and

"

fail high

"

failures as errors and trigger a suitable error message

l

E

xisting communication interfaces

(

e

.

g

.

HART

,

I

²

C

-

B

us

)

are not used for transmission of safety

-

relevant information

T

he measuring system should be used appropriately taking

pressure

,

temperature

,

density

,

dielectric value and chemical

properties of the medium into account

.

I

nstructions to critical process and vessel situations are

described in the operating instructions manual

.

T

he user

-

speci

c limits must be kept

.

T

he speci

cations of the

operating instructions manual must not be exceeded

.

1

.

3

I

nstrument parameter adjustment

S

ince the plant conditions in

uence the safety of the

measuring system

,

the instrument parameters must be set

according to the application

.

T

he following tools are allowed

:

l

the

DTM

suitable for

VEGAPULS

in conjunction with an

adjustment software according to the

FDT

/

DTM

standard

,

e

.

g

.

PACT

ware

l

I

ndicating and adjustment module

N

ote

:

M

ake sure that

DTM

-

C

ollection

10

/

2005

or a newer version is

used

.

A

ssumptions

G

eneral instructions and re

-

strictions

A

djustment tools

VEGAPULS

series

60

-

4

20

m

A

/

HART

7

F

unctional safety

31338

-

EN

-

070510

Содержание VEGAPULS 61

Страница 1: ...Safety Manual VEGAPULS series 60 4 20 mA HART Radar...

Страница 2: ...1 2 Planning 5 1 3 Instrument parameter adjustment 7 1 4 Setup 9 1 5 Reaction during operation and in case of failure 9 1 6 Recurring function test 9 1 7 Safety related characteristics 10 2 VEGAPULS s...

Страница 3: ...le up to SIL2 in a single channel architecture 1oo1D and up to SIL3 in a multiple channel diverse redundant architecture The use of the measuring system in a multiple channel homogeneous redundant arc...

Страница 4: ...for the process industry sector Part 1 Framework de ni tions system hardware and software requirements Failure limit values for a safety function depending on the SIL class of IEC 61508 1 7 6 2 Safety...

Страница 5: ...signal is transmitted to a connected processing unit to monitor the following conditions l Exceeding a preset level l Falling below a preset level When the switching point set on the processing unit i...

Страница 6: ...3 5 12 If the ratio of the internal diagnostics test rate of the measuring system to the demand rate exceeds the value 100 the measuring system can be treated as if it is executing a safety function i...

Страница 7: ...t used for transmission of safety relevant information The measuring system should be used appropriately taking pressure temperature density dielectric value and chemical properties of the medium into...

Страница 8: ...fter connecting the instrument the output signal jumps to the set interference current at the end of the switch on phase l In mode Simulation the signal current can be simulated independent of the act...

Страница 9: ...anual If due to a detected failure the electronics or the complete sensor is exchanged the manufacturer must be informed incl a fault description 1 6 Recurring function test The recurring function tes...

Страница 10: ...7 Safety related characteristics The failure rates of the electronics the mechanical parts of the transmitter as well as the process tting are determined by an FMEDA according to IEC 61508 The calcula...

Страница 11: ...executable sensor software 15 h VEGAPULS 68 and VEGAPULS 61 62 63 with increased sensitivity E013 no measured value available 2 36 min depending on the application E042 E043 hardware error 4 min E036...

Страница 12: ...5 years 4 PFDavg after 10 years Multiple channel architecture If the measuring system is used in a multiple channel architecture the safety relevant characteristics of the selected structure of the m...

Страница 13: ...VEGAPULS series 60 4 20 mA HART 13 Functional safety 31338 EN 070510...

Страница 14: ...14 VEGAPULS series 60 4 20 mA HART Functional safety 31338 EN 070510...

Страница 15: ...VEGAPULS series 60 4 20 mA HART 15 Functional safety 31338 EN 070510...

Страница 16: ...om www vega com ISO 9001 All statements concerning scope of delivery application practical use and operating conditions of the sensors and processing systems correspond to the information avail able a...

Отзывы: