7 Set up with the integrated display and adjustment unit
VEGAMET 342 • 4 … 20 mA
63731-EN-221107
a great distance. The colour of the background lighting changes in the
delivery status according to NAMUR NE 107.
•
White:
Error-free operation
•
Red:
Failure, error, fault
•
Orange:
Function check
•
Blue:
Maintenance required
•
Yellow:
Outside the specification
Alternatively, the status display can also show the switching status of
the relays or measured value ranges individually with freely definable
colours. Up to five measured value ranges, e.g., depending on the
filling level, can be displayed in different colours. The background
lighting can also be configured to flash in any colour as an additional
signalling option.
Information:
This individual colour signalling is configured with PACTware/DTM or
the VEGA Tools app.
The menu items are displayed according to the following presentation:
1
2
Max. adjustment
Sensor value at 100% :
Actual measured sensor value :
19.970
mA
20.000
mA
Fig. 10: Menu item display (example)
1 Sensor measured value at 100 %
2 Current sensor measured value
7.3 Menu overview
Description
Basic settings
Sensor input
Allocation measuring point - input, deactivate
measuring point 2
Damping
Time setting for damping
Linearisation
Linearization settings
Adjustment
Adjustment settings
Scaling
Scaling settings
Outputs
Relay/current output settings
Description
Basic settings
Number of measured
value indications
Number of displayed measured value indications
Menu item display
Measurement loop
Indication