1 For your safety

VEGAFLEX 86 • 4 … 20 mA/HART - two-wire

47615-EN-150102

1  For your safety

1.1  Authorised personnel

All operations described in this operating instructions manual must 

be carried out only by trained specialist personnel authorised by the 

plant operator.
During work on and with the device the required personal protective 

equipment must always be worn.

1.2  Appropriate use

VEGAFLEX 86 is a sensor for continuous level measurement.

You can find detailed information about the area of application in 

chapter "

Product description

".

Operational reliability is ensured only if the instrument is properly 

used according to the specifications in the operating instructions 

manual as well as possible supplementary instructions.

1.3  Warning about incorrect use

Inappropriate or incorrect use of the instrument can give rise to 

application-specific hazards, e.g. vessel overfill or damage to system 

components through incorrect mounting or adjustment.

1.4  General safety instructions

This is a state-of-the-art instrument complying with all prevailing 

regulations and guidelines. The instrument must only be operated in a 

technically flawless and reliable condition. The operator is responsible 

for the trouble-free operation of the instrument.
During the entire duration of use, the user is obliged to determine the 

compliance of the necessary occupational safety measures with the 

current valid rules and regulations and also take note of new regula-

tions.
The safety instructions in this operating instructions manual, the na-

tional installation standards as well as the valid safety regulations and 

accident prevention rules must be observed by the user.
For safety and warranty reasons, any invasive work on the device 

beyond that described in the operating instructions manual may be 

carried out only by personnel authorised by the manufacturer. Arbi-

trary conversions or modifications are explicitly forbidden.

The safety approval markings and safety tips on the device must also 

be observed.

1.5  CE conformity

The device fulfills the legal requirements of the applicable EC guide

-

lines. By affixing the CE marking, we confirm successful testing of the 

product.

You can find the CE Certificate of Conformity in the download section 

of our homepage.

Содержание VEGAFLEX 86

Страница 1: ...Quick setup guide TDR sensor for continuous level and interface measurement of liquids VEGAFLEX 86 4 20 mA HART two wire Coax probe With SIL qualification 196 280 C 196 450 C Document ID 47615...

Страница 2: ...sing 9 4 3 Wiring plan double chamber housing 10 5 Set up with the display and adjustment module 5 1 Insert display and adjustment module 11 5 2 Parameter adjustment 12 6 Supplement 6 1 Technical data...

Страница 3: ...omplying with all prevailing regulations and guidelines The instrument must only be operated in a technically flawless and reliable condition The operator is responsible for the trouble free operation...

Страница 4: ...gle channel operation up to SIL2 The instrument can be used homogeneously redundant up to SIL3 in multi channel architecture with HFT 1 1 7 NAMUR recommendations NAMUR is the automation technology use...

Страница 5: ...Symbol of the device protection class 13 ID numbers instrument documentation 14 Reminder to observe the instrument documentation 15 Notified authority for CE marking 16 Approval directives 17 Marking...

Страница 6: ...4 20 mA HART two wire 47615 EN 150102 Download the smartphone app VEGA Tools from the Apple App Store or the Google Play Store Scan the Data Matrix code on the type label of the instrument or Enter th...

Страница 7: ...s in areas where high humidity is expected e g through cleaning processes Installations on cooled or heated vessels 3 2 Mounting instructions During operation the probe must not touch any installation...

Страница 8: ...ctronics To do this lift the terminal block with a small screwdriver and pull it out When reinserting the terminal block you should hear it snap in Proceed as follows 1 Unscrew the housing cover 2 If...

Страница 9: ...s released the terminal closes again You can find further information on the max wire cross section under Technical data Electromechanical data 7 Check the hold of the wires in the terminals by lightl...

Страница 10: ...uble chamber housing The following illustrations apply to the non Ex as well as to the Ex ia version 5 1 2 6 7 8 4 20mA Display 2 3 4 1 Fig 6 Terminal compartment double chamber housing 1 Voltage supp...

Страница 11: ...by 90 It is not necessary to interrupt the power supply Proceed as follows 1 Unscrew the housing cover 2 Place the display and adjustment module on the electronics in the desired position and turn it...

Страница 12: ...rameter adjustment 1 In this menu item you can select the application You can choose between level and interface measurement 2 In the menu item Medium Dielectric constant you can define the type of me...

Страница 13: ...a no measurement is possible 5 Lower dead band in this area no measurement is possible For this adjustment the distance is entered when the vessel is full and nearly empty If these values are not know...

Страница 14: ...Operating voltage Non Ex instrument Ex d instrument 9 6 35 V DC Ex ia instrument 9 6 30 V DC Ex d ia instrument 15 35 V DC Operating voltage with illuminated display and adjustment module Non Ex inst...

Страница 15: ...15 Notes VEGAFLEX 86 4 20 mA HART two wire 47615 EN 150102...

Страница 16: ...of delivery application practical use and operat ing conditions of the sensors and processing systems correspond to the information available at the time of printing Subject to change without prior n...

Отзывы: