55
10 Supplement
VEGABAR 87 • Modbus and Levelmaster protocol
46297-EN-220624
Additional factor through measuring cell version
Measuring cell ver-
sion
Measuring cell -
Standard
Measuring cell climate-compensated, depending on measur-
ing range
0.1 %
10 bar, 25 bar
1 bar, 2.5 bar
0.4 bar
Factor FMZ
1
1
2
3
Additional factor through Turn Down
The additional factor FTD through Turn down is calculated according to the following formula:
F
TD
= 0.5 x TD + 0.5
In the table, example values for typical Turn downs are listed.
Turn Down
TD 1 : 1
TD 2.5 : 1
TD 5 : 1
TD 10 : 1
TD 20 : 1
Factor FTD
1
1.75
3
5.5
10.5
Long-term stability (according to DIN 16086)
Applies to the respective
digital
signal output (e.g. HART, Profibus PA) as well as to
analogue
cur-
rent output 4 … 20 mA under reference conditions. Specifications refer to the set span. Turn down
(TD) is the ratio nominal measuring range/set span.
Long-term stability zero signal and output span
Time period
All measuring ranges
Measuring range
0 … +0.025 bar/0 … +2.5 kPa
One year
< 0.05 % x TD
< 0.1 % x TD
Five years
< 0.1 % x TD
< 0.2 % x TD
Ten years
< 0.2 % x TD
< 0.4 % x TD
Long-term stability zero signal and output span - version climate-compensated
Nominal measuring range in bar/kPa
Nominal measuring range
in psig
0 … 10 bar/0 … 1000 kPa
0 … 150 psig
< (0.1 % x TD)/year
0 … 25 bar/0 … 2500 kPa
0 … 350 psig
0 … 1 bar/0 … 100 kPa
0 … 15 psig
< (0.25 % x TD)/year
0 … 2.5 bar/0 … 250 kPa
0 … 35 psig
0 … 0.4 bar/0 … 40 kPa
0 … 6 psig
< (1 % x TD)/year
Ambient conditions
Version
Ambient temperature
Storage and transport temperature
Version with connection tube
-40 … +80 °C (-40 … +176 °F) -60 … +80 °C (-76 … +176 °F)
Version with FEP suspension cable
-20 … +80 °C (-4 … +176 °F)
-20 … +80 °C (-4 … +176 °F)
Version IP68 (1 bar) with connection
cable PE
-20 … +60 °C (-4 … +140 °F)
-20 … +60 °C (-4 … +140 °F)