Vega VEGABAR 81 Скачать руководство пользователя страница 14

12

O

peration

12

.

1

O

verview

T

he sensors can be adjusted with the following adjustment media

:

l

W

ith the display and adjustment module

l

W

ith external display and adjustment unit

l

an adjustment software according to

FDT

/

DTM

standard

,

e

.

g

.

PACT

ware and

PC

as well as via systems from other manufacturers

,

dependent on the signal

output

:

l

A HART

handheld

(

4

20

m

A

/

HART

)

l

T

he adjustment program

AMS

(

4

20

m

A

/

HART

and

F

oundation

F

ieldbus

)

l

T

he adjustment program

PDM

(

P

ro

bus

PA

)

l

A

con

guration tool

(

F

oundation

F

ieldbus

)

T

he entered parameters are generally saved in the sensor

,

optionally also

in the display and adjustment module or in the adjustment program

.

12

.

2

D

isplay and adjustment module

PLICSCOM

T

he pluggable display and adjustment module is used for measured value

indication

,

operation and diagnosis

.

I

t is equipped with an illuminated full

dot matrix as well as four keys for adjustment

.

F

ig

.

32

:

D

isplay and adjustment module

PLICSCOM

T

he display and adjustment module is integrated in the respective sensor

housing or in the external display and adjustment unit

.

A

fter mounting

,

the

sensor as well as the display and adjustment module are splash

-

proof

even without housing cover

.

12

.

3

PACT

ware

/

DTM

A

s an alternative to the display and adjustment module

,

the sensor can

also be con

gured via a

W

indows

PC

.

T

o do this

,

the con

guration soft

-

ware

PACT

ware and a suitable instrument driver

(

DTM

)

according to the

FDT

standard are required

.

T

he current

PACT

ware version as well as all

available

DTM

s are compiled in a

DTM C

ollection

.

T

he

DTM

s can also be

integrated into other frame applications according to the

FDT

standard

.

A

ll device

DTM

s are available as a free

-

of

-

charge standard version and as

a full version that must be purchased

.

I

n the standard version

,

all functions

for complete setup are already included

.

A

n assistant for simple project

con

guration simpli

es the adjustment considerably

.

S

aving

/

printing the

project as well as import

/

export functions are also part of the standard

version

.

I

n the full version there is also an extended print function for complete

project documentation as well as a save function for measured value and

echo curves

.

I

n addition

,

there is a tank calculation program as well as a

multiviewer for display and analysis of the saved measured value and
echo curves

.

C

onnection of the

PC

via

VEGACONNECT

T

he interface converter

VEGACONNECT

is required for connection of the

PC

.

O

n the computer side

,

the connectionis made via

USB

interface

.

T

he

VEGACONNECT

is placed instead of the display and adjustment module

to the sensor

,

the connection to the sensor is made automatically

.

A

s an

alternative the connection via the

HART

signal can be carried out on any

position of the signal cable with

4

20

m

A

/

HART

sensors

.

3

1

USB

2

OP

EN

TWIST

LOCK

F

ig

.

33

:

C

onnection via

VEGACONNECT

and

USB

1

VEGACONNECT

2

plics

®

sensor

3

USB

cable to the

PC

N

ecessary components

:

l

VEGABAR

l

PC

with

PACT

ware and suitable

DTM

l

VEGACONNECT

l

V

oltage supply

/

P

rocessing system

12

.

4

A

lternative adjustment programs

PDM

F

or

HART

and

P

ro

bus

PA

sensors

,

device descriptions are available as

EDD

s for the adjustment program

PDM

.

T

he device descriptions are al

-

ready included in the current version of the

PDM

.

N

ewer instrument driv

-

ers that are not yet delivered with the

PDM

are available in the download

section

.

AMS

F

or

HART

and

F

oundation

F

ieldbus sensors

,

device descriptions are

available as

EDD

s for the adjustment program

AMS

.

T

he device descrip

-

tions are already included in the current version of the

AMS

.

N

ewer instru

-

ment drivers that are not yet delivered with the

AMS

are available in the

download section

.

O

peration

14

P

rocess pressure

P

ressure transmitter

45078

-

EN

-

140625

Содержание VEGABAR 81

Страница 1: ...Process pressure Pressure transmitter VEGABAR 81 82 83 Product Information ...

Страница 2: ... differential pressure 13 12 Operation 14 13 Dimensions 15 Take note of safety instructions for Ex applications Please note the Ex specific safety information which you can find on our homepage www vega com downloads under Approvals and which comes with every instrument In hazardous areas you should take note of the corresponding regulations conformity and type approval certificates of the sensors and...

Страница 3: ...ement is the CERTEC measuring cell with front flush abrasion resistant ceramic diaphragm The hydrostatic pressure of the medium or the process pressure causes a capacitance change in the measuring cell via the diaphragm This change is converted into an ap propriate output signal 16 µm 1 2 3 Fig 2 Configuration of the CERTEC measuring cell in VEGABAR 82 1 Diaphragm 2 Soldered glass bond 3 Base elemen...

Страница 4: ...ic 316Ti Elgiloy 2 4711 Alloy C276 gold coated gold rhodi um coated Measuring cell seal FKM EPDM FFKM Isolating liquid Silicone oil high temperature oil halocarbon oil med white oil Dry measuring system Silicone oil Halocarbon oil Med white oil Measuring range 1 1000 bar 100 100 MPa 14 5 14500 psig 1 100 bar 100 10 MPa 14 5 1450 psig 1 1000 bar 100 100 MPa 14 5 14500 psig Smallest measuring range ...

Страница 5: ...g with electronics 3 Process fitting with measuring cell 1 2 3 4 5 Fig 6 Example of a VEGABAR 82 with flange and aluminium housing in protection IP 66 IP 68 1 bar 1 Housing cover with integrated display and adjustment module optional 2 Housing with electronics 3 Process fitting with measuring cell 4 Cable gland 5 Connection cable 1 2 3 5 4 Fig 8 Example of a VEGABAR 82 with flange and stainless steel ...

Страница 6: ... MPa 400 bar 40 MPa 1000 bar 100 MPa Smallest measuring range 400 mbar 40 kPa 100 mbar 10 kPa 25 mbar 2 5 kPa Vacuum applications up to 1 mbarabs 100 Pa Suitability for industry specific ap plications Aggregates and min ing industry Chemical Power generation Foodstuffs Metal production Offshore Paper Petrochemical Pharmaceutical Shipbuilding Environment and recy cling industry Water waste water Cemen...

Страница 7: ...ss Stainless steel 316L Protection rating IP 66 IP 67 IP 69K IP 66 IP 67 IP 66 IP 68 1 bar Version Single chamber electropolished Single chamber precision casting Double chamber precision casting Application area Aggressive environment food pro cessing pharmaceutical Aggressive environment extreme mechanical stress Separate version Material Stainless steel 316L plastic PBT Stainless steel 316L Pro...

Страница 8: ...a pipeline Fig 12 Process pressure measurement on a pipeline with VEGABAR Level measurement The VEGABAR measures the level in a vessel Fig 14 Level measurement in a vessel with VEGABAR Differential pressure measurement The VEGABAR measures the pressure difference between input and output of a filter Fig 16 Differential pressure measurement on a filter with VEGABAR and Slave sensor Flow measurement The ...

Страница 9: ... additional factors that influence the operating voltage l Lower output voltage of the power supply unit under nominal load e g with a sensor current of 20 5 mA or 22 mA in case of fault l Influence of additional instruments in the circuit see load values in chapter Technical data of the operatinginstructionsof the respective instrument Connection cable The instrument is connected with standardtwo w...

Страница 10: ...0 5 mA or 22 mA in case of fault l Influence of additional instruments in the circuit see load values in chapter Technical data of the operatinginstructionsof the respective instrument Connection cable The instrument is connected with standardtwo wire cable without screen If electromagnetic interference is expected which is above the test values of EN 61326 1 for industrial areas screened cable sho...

Страница 11: ... screening and grounding Insystemswithpotentialequalisation connectthecablescreendirectlyto ground potential at the power supply unit in the connection box and at the sensor The screen in the sensor must be connected directly to the inter nal ground terminal The ground terminal outside on the housing must be connected to the potential equalisation low impedance In systems without potential equalis...

Страница 12: ...and grounding Insystemswithpotentialequalisation connectthecablescreendirectlyto ground potential at the power supply unit in the connection box and at the sensor The screen in the sensor must be connected directly to the inter nal ground terminal The ground terminal outside on the housing must be connected to the potential equalisation low impedance In systems without potential equalisation conne...

Страница 13: ...to the sensor with standard four wire screened cable In the product configurator of VEGABAR different cable glands are avail able This selection covers all cable diameters in the range of 4 12 mm 0 16 0 47 in Cable screen and grounding Connect the cable screen on both ends to ground potential In VEGABAR Slave and Master sensor the screen must be connected directly to the internal ground terminal The...

Страница 14: ...rd version all functions for complete setup are already included An assistant for simple project configuration simplifies the adjustment considerably Saving printing the project as well as import export functions are also part of the standard version In the full version there is also an extended print function for complete project documentation as well as a save function for measured value and echo ...

Страница 15: ...sion casting 2 Double chamber housing precision casting VEGABAR 81 109 mm 4 29 89 mm 3 5 D 1 2 1 Flange version 2 Version with tube isolating diaphragm VEGABAR 82 2 3 1 20 8 mm 0 82 45 mm 1 77 SW 27 mm 1 06 G ø 18 4 mm 0 72 ø 27 mm 1 06 G1 50 mm 1 97 22 mm 0 87 ø 55 mm 2 17 SW 46 mm 1 81 50 mm 1 97 1 Threaded version G1 A 2 Threaded version G A inner G A 3 Threaded version G A inner G A PVDF VEGAB...

Страница 16: ... 7836 50 0 Fax 49 7836 50 201 E Mail info de vega com www vega com You can find at www vega com l operating instructions manuals l specification sheet l Software l drawings l certificates l approvals and much much more Subject to change without prior notice 45078 EN 140625 ...

Отзывы: