9
E
lectronics
-
P
ro
fi
bus
PA
C
on
fi
guration of the electronics
T
he pluggable electronics is mounted in the electronics compartment of
the instrument and can be exchanged by the user when servicing is re
-
quired
.
T
he electronics is completely encapsulated to protect against
vibration and moisture
.
T
he terminals for voltage supply as well as the plug with
I
²
C
interface for
parameter adjustment are located on the upper side of the electronics
.
I
n
the double
-
chamber housing
,
these connection elements are located in
the separate terminal compartment
.
V
oltage supply
T
he voltage supply is provided by a
P
ro
fi
bus
DP
/
PA
segment coupler
.
D
ata of the voltage supply
:
l
O
perating voltage
-
9
…
32
V DC
l
M
ax
.
number of sensors per
DP
/
PA
segment coupler
-
32
C
onnection cable
C
onnection is carried out with screened cable according to
P
ro
fi
bus spec
-
i
fi
cation
.
I
n the product con
fi
gurator of
VEGABAR
,
di
ff
erent cable glands are avail
-
able
.
T
his selection covers all cable diameters in the range of
4
…
12
mm
(
0
.
16
…
0
.
47
in
).
M
ake sure that the entire installation is carried out according to the
P
ro
-
fi
bus speci
fi
cation
.
I
n particular
,
make sure that the bus is terminated with
suitable terminating resistors
.
C
able screening and grounding
I
n systems with potential equalisation
,
connect the cable screen directly to
ground potential at the power supply unit
,
in the connection box and at the
sensor
.
T
he screen in the sensor must be connected directly to the inter
-
nal ground terminal
.
T
he ground terminal outside on the housing must be
connected to the potential equalisation
(
low impedance
).
I
n systems without potential equalisation
,
connect the cable screen di
-
rectly to ground potential on the power supply unit and the sensor
.
I
n the
connection box or
T
-
distributor
,
the screen of the short stub to the sensor
must not be connected to ground potential or to another cable screen
.
C
onnection
S
ingle chamber housing
5
0
0
5
1
6
2
7
3
8
4
9
0
5
1
6
2
7
3
8
4
9
1
0
1
6
7
8
Bus
2
3
4
5
1
2
+
( )
(-)
1
F
ig
.
27
:
E
lectronics and terminal compartment
,
single chamber housing
1
V
oltage supply
/
S
ignal output
2
F
or display and adjustment module or interface adapter
3
S
election switch for bus address
4
F
or external display and adjustment unit
5
G
round terminal for connection of the cable screen
D
ouble chamber housing
Bus
5
1
2
+
( )
(-)
6
7
8
2
3
4
1
F
ig
.
28
:
T
erminal compartment
,
double chamber housing
1
V
oltage supply
/
S
ignal output
2
F
or display and adjustment module or interface adapter
3
G
round terminal for connection of the cable screen
E
lectronics
-
P
ro
fi
bus
PA
P
rocess pressure
–
P
ressure transmitter
11
45078
-
EN
-
140625