45
13 Supplement
VEGABAR 29 • Two-wire 4 … 20 mA
57087-EN-210301
Frequency
2.402 … 2.480 GHz
Max. emitted power
+2.2 dBm
Max. number of participants
1
Effective range typ.
13)
25 m (82 ft)
Electromechanical data
Angled plug connector
Ʋ
Version
4-pin according to ISO 4400
Ʋ
Cable gland
M16 x 1.5 (for cable diameter 4.5 … 7 mm)
Ʋ
Screw terminals for cable cross-
section up to
1.5 mm² (AWG 15)
Angle plug connector with flap lid
Ʋ
Version
4-pin according to ISO 4400
Ʋ
Cable gland
M16 x 1.5 (for cable diameter 4.5 … 11 mm)
Ʋ
Screw terminals for cable cross-
section
up to 1.5 mm² (AWG 15)
Angled plug connector with IDC method of termination
Ʋ
Version
4-pin according to ISO 4400
Ʋ
Wire cross-section
0.5 … 1 mm² (AWG 20 … AWG 17)
Ʋ
Strand diameter
> 0.1 mm
Ʋ
Wire diameter
1.6 … 2 mm
Ʋ
Outer cable diameter
5.5 … 8 mm
Ʋ
Connection frequency (on the same
cross-section)
10 x
Round plug connector
4-pole with M12 x 1 screw connection
Direct cable outlet
Ʋ
Length
5 m (16.4 ft), 10 m (32.81 ft), 25 m (82.02 ft)
Ʋ
Wire cross-section
0.34 mm² (AWG 21)
Ʋ
Diameter two-wire
approx. 6 mm
Ʋ
Diameter three-wire
approx. 8 mm
Ʋ
Min. bending radius (at 25 °C/77 °F)
25 mm
Voltage supply
Operating voltage U
B
12 … 35 V DC
Reverse voltage protection
Integrated
Permissible residual ripple
Ʋ
for U
N
12 V DC (12 V < U
B
< 18 V)
≤ 0.7 V
eff
(16 … 400 Hz)
Ʋ
for U
N
24 V DC (18 V < U
B
< 35 V)
≤ 1.0 V
eff
(16 … 400 Hz)
Load resistor
Ʋ
Calculation
(U
B
- U
min
)/0.022 A
13)
Depending on the local conditions; with M12 x 1 plug stainless steel (closed full metal housing) effective range
up to approx. 5 m (16.40 ft)