VEGA SI-13/User Manual
27
Revision 08 – 04 May 2018
3.
Command for an extraordinary survey of the connected meter
Size in bytes
Field description
1 byte
Packet type, this packet = 6
1 byte
Meter type. May be equal to:
1 – Single-phase electric meter Mercury 20X series
4 bytes
Meter address
After receiving this command SI-13 will poll the meter with the specified address. Based
on the results of the survey, a packet will be sent with the current readings of the connected
meter.