Mounting Facilities
You can also mount the source container on a mounting plate provided by the
customer or on an L-Profile.
Figure 4.9
Mounting Facility Supplied by Customer - Hole Pattern
1. Mounting Plate
2. L-profiles
Installation Control
Measurement of Local Dose Rate
After mounting, or as soon as the radioactive emitter is mounted in the source
holder
,
you must measure the local dose rate in the area of the source holder and
the detector.
Depending on the respective installation, radiation can also leak out
of the beam exit channel due to scattering. Make sure stray
radiation is shielded off with additional lead or steel sheets. Also,
make certain all control and off-limit areas are not accessible and
marked with warning signs
.
!
CAUTION
Содержание SHLD 2
Страница 1: ...Operating Instructions SHLD 2 Source Holder Document ID 63138 Radiometric...
Страница 2: ......
Страница 8: ...6 63138 US 200110 NOTES...
Страница 12: ...10 63138 US 200110 NOTES...
Страница 26: ...24 63138 US 200110 NOTES...
Страница 42: ...40 63138 US 200110 NOTES...
Страница 56: ...54 63138 US 200110 NOTES...
Страница 68: ...66 63138 US 200110 NOTES...
Страница 78: ...76 63138 US 200110 9 2 Dimensions Figure 9 7 Source Holder SHLD 2 Standard Version...
Страница 79: ...63138 US 200110 77 Figure 9 8 SHLD 2 Beam Angles Figure 9 9 SHLD 2 Height for Source Exchange...
Страница 80: ...78 63138 US 200110 Figure 9 10 Source Holder SHLD 2 with Limit Switch...
Страница 81: ...63138 US 200110 79 Figure 9 11 Source Holder SHLD 2 with Interlock Safety Switch...
Страница 82: ...80 63138 US 200110 Figure 9 12 Source Holder SHLD 2 with Air Actuator...
Страница 83: ...63138 US 200110 81 Figure 9 13 Source Holder SHLD 2 with Air Actuator and Limit Switch...
Страница 84: ...82 63138 US 200110 Figure 9 14 Source Holder SHLD 2 Explosion Proof with Limit Switch...
Страница 86: ...84 63138 US 200110 NOTES...
Страница 87: ......