8
Available symbols:
Menu 7
: It allows to set the input time reading
Press seven times the
T1
(SELECT) button, the display will show the writing “
P7
”;
Press the
T2
(ENTER) button to access the programming menu (digits show the current value);
Using the
T1
(SELECT) button it is possible to choose the value:
1=50 ms, 2=100 ms, 3=150 ms, 4=200ms, 5=250ms, 6=300 ms, 7=350 ms, 8 =400 ms,
9=450ms, 10=500ms
Press
T2
(ENTER) button to confirm the value.
MENU SUMMARY:
Menu
Range
Default
Description
1
1P-B-BN-G
1P
Modify the coding mode used by the board.
2
-9…+9
-1
Assign the value visualized at the first floor. The
values visualized at the other floors will be
automatically worked out by the board
3
0-3
0
Enables the expansions number (ENCSER_EXP)
(max 3)
4
0-1
1
Enable the input for overload, gong and out of service.
5
-9…22
-9…22
Assign a characters for each selected floor.
6
0-1
0
0=normal working;
1=Floor memorizing (all-off inputs the board only
memorize the last valid floor)
7
1-10
1
Input debounce time (value for x50 ms.)
1=50 ms ;
2=100 ms;
…
10=500 ms
NOTE:
to RESET the board press
ENTER (T2)
for at least 5 seconds (valid in each
moment). The display will show “ME” to confirm the reset (default values).
ENCSER_EXP
In case the available inputs on the ENCSER (in 1 wire per floor working mode) should not be
enough, it is possible to connect on the ENCSER board some (ENCSER_EXP) expansion boards
(up to 3).