Vega Technologies CP-03 Скачать руководство пользователя страница 4

               

R404-1 

 

III.   Important Safeguards 
Note

: Read all instructions carefully before use. 

The following basic precautions are needed when using an electrical product: 

Caution:

 Failure to read and observe all precautions could result in personal 

injury or equipment damage. 
 

Product cautions: 

 

1.  To avoid electrical shock: Keep the unit away from water

Do not immerse the 

power cord or the unit in liquid

Do not use while bathing

Do not reach for a 

unit that has fallen into water – immediately unplug the unit. 

2.  Never operate the unit if it has any damaged parts (including power cord), if it 

has been dropped or submersed in water. Promptly send it to a service center 
for examination and repair. 

3.  The unit should not be used where flammable gas, oxygen or aerosol spray 

products are being used. 

4.  Disconnect the unit from the electrical outlet before cleaning, filling and after 

each use. 

5.  Do not use other attachments unless recommended by manufacturer. 

 
Operating Cautions: 

 

1.  Connect this product to an appropriate voltage outlet for your model. 
2.  Do not run this product unattended. 
3.  Never operate if this unit has a damaged cord or plug, and if it has been 

dropped into water. 

4.  If any abnormality occurs, discontinue use immediately until the unit has been 

examined and repaired. 

5.  Always unplug the product immediately after use. 
 

Storage Cautions: 

 

1.  Do not store the unit under direct sunlight, high temperature or humidity. 
2.  Keep the unit out of reach of small children. 
3.  Always keep the unit unplugged while not in use. 
 

Cleaning Cautions: 

 

1.  Do not immerse the unit in water. It may damage the unit. 
2.  Disconnect the unit from the electrical outlet before cleaning. 
Clean all necessary parts after each use as instructed in this guidebook 

Содержание CP-03

Страница 1: ...1 INSTRUCTION VEGA MANUAL Continuous Positive Airway Pressure MODEL CP 03 READ THIS INSTRUCTION Version 1 0 Date Nov 04 2009 ISO9001 ISO13485 Certified This device complies with EU EMC standard EN6060...

Страница 2: ...device uses a motor which drives a fan to create a continuous air pressure to force the air into the patient s lung through the nasal cavity so that the patient s airway is expedite which is the key t...

Страница 3: ...R404 1 B Assemblies...

Страница 4: ...cts are being used 4 Disconnect the unit from the electrical outlet before cleaning filling and after each use 5 Do not use other attachments unless recommended by manufacturer Operating Cautions 1 Co...

Страница 5: ...upply 12V DC 2 Current Consuming Max 1 5A 3 Air Pressure Range 3 cmH2O 20 cmH2O 4 Ramp Time 0 60 min 5 Air Pressure Calibrate 3 cmH2O 6 Working Flow 3 0 3m 3 h 9 cmH2O 7 Noise 33 dB 9 cmH2O 1m away 8...

Страница 6: ...nd the device returns to the standby mode 4 Press RAMP at the normal working mode CPAP runs at the ramp mode the LCD outputs RAMP and Pressure xx x cmH2o xx x is the numeric value of the air pressure...

Страница 7: ...ing on the screen the LCD displays Mask Off meanwhile the backlight flashes at the frequency of 1 Hz for 1 minute The following are configuration operations 5 Press RAMP and at the same time in standb...

Страница 8: ...feet 2500 5000 feet 5000 7500 feet and 7500 9000 feet respectively Set this with and according to the altitude of your current location 8 Press MODE at the altitude setting mode the device enters the...

Страница 9: ...Press MODE at the ramp time setting mode the device enters the starting air pressure setting mode The LCD displays Ramp Start Pressure xx x cmH2o xx x is the numeric value of the starting air pressur...

Страница 10: ...he operation time checking mode The LCD displays Operation Hrs xxxx x xxxx x is the operation time of the device This value is not to be changed but only to be reset Press for a period of time of 2 se...

Страница 11: ...on the screen Disconnect the USB cable the device goes back to Standby mode VI Cleaning and Sterilization It is recommended that the air tube and mask be thoroughly cleaned with hot water after each u...

Страница 12: ...Submerge these parts in the vinegar and water solution for thirty minutes 5 Complete Rinsing Steps 3 5 Filter change 1 Do not wash or clean the filter And do not operate without a filter 2 Change the...

Страница 13: ...R404 1 Consult accompanying documents Type BF equipment Disposal for separate collection Device in protection class 2...