“VEGA SI-21” TAB
The “Vega SI-21” tab contains the settings of the connected device.
Current state
– displays the current parameters of the device - the number of counted
pulses at the inputs, the external thermistor temperature, and the battery level.
To reset the pulse count at the inputs, it is necessary to put the device in the "Storage"
mode by pressing the button on the board for a long time (more than 5 seconds) (see section
"Initial startup").
Input settings
– allows setting up the current mode of inputs from pulse to guard and
back. When you switch the input to the security mode, the device will send an alarm packet to
the network (see part 5, packet 2) whenever this input is triggered. The maximum possible
frequency of alarm packets generation is one per second.